2020
DOI: 10.1016/j.jare.2020.06.019
|View full text |Cite
|
Sign up to set email alerts
|

3D printed solution flow type microdroplet cell for simultaneous area selective anodizing

Abstract: Graphical abstract

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
5
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 39 publications
0
5
0
Order By: Relevance
“…Without this support structure, Sf-MDC with coaxial dual capillaries cannot be printed accurately. Since the fabricated Sf-MDC is affected by the printing direction and the resolution of the 3D printer, 25,26 the fine structure (inner capillary, solution inlet tube etc) was inspected carefully during the manufacture. After confirming that the structure is printed properly, the Sf-MDC was washed in 2-propanol and allowed to cure for 30 min.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Without this support structure, Sf-MDC with coaxial dual capillaries cannot be printed accurately. Since the fabricated Sf-MDC is affected by the printing direction and the resolution of the 3D printer, 25,26 the fine structure (inner capillary, solution inlet tube etc) was inspected carefully during the manufacture. After confirming that the structure is printed properly, the Sf-MDC was washed in 2-propanol and allowed to cure for 30 min.…”
Section: Resultsmentioning
confidence: 99%
“…The solution inlet was connected to a pump by a silicone tube (diameter; 2 mm) and the solution outlet was connected to an aspirator (ULVAC KIKO Inc., MDA-015). 25 The flow rate of the solution was controlled at 1.0 × 10 -3 cm 3 s −1 using a pump (ATTO Corp., SJ-1211), and aspirated at around 90 kPa with an aspirator. The solution was 10 mol m −3 NaCl.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…No matter how the MCC technique progresses, its basic configuration is similar. The capillary tip made of glass is usually fabricated by laser/heat-assisted pulling, and that made of organic materials is created by high-precision machining or 3D-printing techniques. As for organic materials, with either the machining or the 3D-printing method, higher fabrication accuracy is necessary to reduce the tip diameter for higher spatial resolution. , In fact, the current resolution of the potentiostat, not the tip diameter of the microcapillary, is what determines the minimum lateral resolution. , The improved current resolution (<1 fA) allows the electrochemical tests to be performed on an exposed area even below 1 μm…”
Section: Microcapillary Cell Techniquementioning
confidence: 99%
“…Robust, reproducible and cost-effective fabrication of metals at micrometer scale would enable rapid development of advance electronic devices, microelectromechanical systems (MEMS) and biomedical devices [1][2][3][4][5][6]. Conventionally, mask-based lithography is the main standard of industries to produce micro-or nano-scale patterns.…”
Section: Introductionmentioning
confidence: 99%