2018
DOI: 10.1016/j.jcot.2018.07.009
|View full text |Cite
|
Sign up to set email alerts
|

3D printing in designing of anatomical posterior column plate

Abstract: This was a pilot study and we need a large sample size to study accuracy of our acetabular plate design which might avoid intra-operative contouring, decreasing morbidity of patient and prevent wastage of resources in pre-operative planning and computer designing.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
2

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 16 publications
0
4
0
Order By: Relevance
“…Some specialists can make customized osteosynthesis and surgical jigs via the 3D-printing technique. Maini et al [ 10 ] designed an anatomical posterior column plate for Indian origin via virtual simulation and 3D-printed plastic template to match the surface, and good quality of reduction was reported with this method. Merema et al [ 11 ] claimed that 3D printing and patient-based surgical guides are achievable and auspicious for the operative treatment of acetabular fractures.…”
Section: Discussionmentioning
confidence: 99%
“…Some specialists can make customized osteosynthesis and surgical jigs via the 3D-printing technique. Maini et al [ 10 ] designed an anatomical posterior column plate for Indian origin via virtual simulation and 3D-printed plastic template to match the surface, and good quality of reduction was reported with this method. Merema et al [ 11 ] claimed that 3D printing and patient-based surgical guides are achievable and auspicious for the operative treatment of acetabular fractures.…”
Section: Discussionmentioning
confidence: 99%
“…Case series focused on subjective measures. Clinical outcomes in all cases were satisfactory, with some of that success attributed to the use of 3D models.…”
Section: Resultsmentioning
confidence: 99%
“…This can cause irritation to the surrounding soft tissues and increase patient pain. 9,10,14,16,22 Third, the neck of the scapula can only accommodate 2 screws, making fracture fixation unreliable, increasing the risk of fixation failure. Fourth, the direction of the screws around the joint cannot be controlled, which increases the risk of the screws entering the joint cavity; because there are important nerves and blood vessels in the neck of the scapula, exposure is not easy to achieve.…”
Section: Discussionmentioning
confidence: 99%