2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149)
DOI: 10.1109/nssmic.2000.950108
|View full text |Cite
|
Sign up to set email alerts
|

3D reconstruction in PET cameras with irregular sampling and depth of interaction

Abstract: Abstract--We present 3D reconstruction algorithms that address fully 3D tomographic reconstruction using septa-less, stationary, and rectangular cameras. The field of view (FOV) encompasses the entire volume enclosed by detector modules capable of measuring depth of interaction (DOI). The Filtered Backprojection based algorithms incorporate DOI, accommodate irregular sampling, and minimize interpolation in the data by defining lines of response between the measured interaction points. We use fixed-width, evenl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Publication Types

Select...
1
1
1

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…The image reconstruction task for this scanner has been subject of an intense work. In an initial stage, image reconstruction was performed with a filtered backprojection based reconstruction algorithm that took into account the existence of DOI information and the irregular angular sampling of the scanner [43,44]. Later, a list mode penalized maximum likelihood algorithm using Gaussian priors was developed [40,45,46].…”
Section: The Lbnl Pem Systemmentioning
confidence: 99%
“…The image reconstruction task for this scanner has been subject of an intense work. In an initial stage, image reconstruction was performed with a filtered backprojection based reconstruction algorithm that took into account the existence of DOI information and the irregular angular sampling of the scanner [43,44]. Later, a list mode penalized maximum likelihood algorithm using Gaussian priors was developed [40,45,46].…”
Section: The Lbnl Pem Systemmentioning
confidence: 99%
“…We have developed and tested both filtered backprojection reconstruction algorithms (2-D [10] and 3-D [11]) and a list mode regularized maximum likelihood reconstruction algorithm [12] using Monte Carlo data. The rectangular geometry and the capability of measuring DOI result in irregular sampling in the sinogram space.…”
Section: Reconstructionmentioning
confidence: 99%
“…Dedicated PET, commonly referred to as positron emission mammography (PEM), has been developed for imaging breast [1], [2], [3], [4]. Comparing to whole body PET scanners, PEM scanners are built with much less number of detector modules and have higher sensitivity.…”
Section: Introductionmentioning
confidence: 99%
“…For this scanner, we have developed image reconstruction algorithms, including a filtered backprojection algorithm [4] and a list mode likelihood reconstruction algorithm [5]. In [6] we have also theoretically studied the resolution and noise properties of the list mode reconstruction.…”
Section: Introductionmentioning
confidence: 99%