2018
DOI: 10.1007/s00404-018-4842-1
|View full text |Cite
|
Sign up to set email alerts
|

3D vocal power Doppler sonography for the estimation of tumor volume and vascularization in stage IB1 cervical cancer

Abstract: 3-D VOCAL-PD is extremely accurate and superior to 2D ultrasound for the estimation of tumor volume and vascularization when it is more than 2.5 cm and has a complex vascularization in patients with stage 1B1 cervical cancer.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 18 publications
0
3
0
Order By: Relevance
“…The increase of the vascular malformation rate causes significant changes in the hemodynamics of patients. However, the analysis of ultrasonic indicators of patients has a number of limitations in the diagnosis of cervical cancer ( 23 ), because benign lesions of the cervix may cause significant changes of regional blood parameters as well. Consequently, if an ultrasound is the only instrument used, it can easily result in false positives in clinical diagnoses.…”
Section: Discussionmentioning
confidence: 99%
“…The increase of the vascular malformation rate causes significant changes in the hemodynamics of patients. However, the analysis of ultrasonic indicators of patients has a number of limitations in the diagnosis of cervical cancer ( 23 ), because benign lesions of the cervix may cause significant changes of regional blood parameters as well. Consequently, if an ultrasound is the only instrument used, it can easily result in false positives in clinical diagnoses.…”
Section: Discussionmentioning
confidence: 99%
“…For evaluating the tumor's volume and intra-tumoral vascularization, the study enrolled 27 patients, with cervical cancer and stage 1B1 disease, who have an initial 2D ultrasound examination and followed by 3D volumes of the cervix. The Virtual Organ Computer Aided Analysis (VOCAL) program was used to calculate the tumor volume and vascularization [23]. For tumors equal or smaller than 2.5 cm3 with linear vascularity, a significant superiority of 2D ultrasound over 3D VOCAL-PD was demonstrated; for larger tumor volume with complex vascularization, a superiority of 3D VOCAL-PD was revealed [23].…”
Section: Local Staging Of Cervical Cancermentioning
confidence: 99%
“…The Virtual Organ Computer Aided Analysis (VOCAL) program was used to calculate the tumor volume and vascularization [23]. For tumors equal or smaller than 2.5 cm3 with linear vascularity, a significant superiority of 2D ultrasound over 3D VOCAL-PD was demonstrated; for larger tumor volume with complex vascularization, a superiority of 3D VOCAL-PD was revealed [23]. Therefore, 3-D VOCAL-PD is superior to 2D ultrasound for calculating tumor volume and vascularization when tumor is more than 2.5 cm3 and show a complex vascularization in women with stage 1B1 cervical cancer [23].…”
Section: Local Staging Of Cervical Cancermentioning
confidence: 99%