“…The basic model of the block was consid ered elsewhere [13]. Atomization block was mounted at a Saturn 2 AA spectrophotometer and another apparatus with a deuterium background corrector [7,9,13]. Before the experiments, graphite atomizerevaporators were annealed at a temperature of 2500°C to eliminate impurities.…”
Section: Electrothermal Atomizer-evaporators: Equipmentmentioning
confidence: 99%
See 2 more Smart Citations
“…The basic model of the block was consid ered elsewhere [13]. Atomization block was mounted at a Saturn 2 AA spectrophotometer and another apparatus with a deuterium background corrector [7,9,13]. Before the experiments, graphite atomizerevaporators were annealed at a temperature of 2500°C to eliminate impurities.…”
Section: Electrothermal Atomizer-evaporators: Equipmentmentioning
confidence: 99%
“…The technique is given in [7]. The duration of sorption (50 mL of the sample and 50 mg of the sorbent) with stirring was 60 min.…”
Section: Preparation Of Unfiltered and Filtered Water Samples In A Crmentioning
confidence: 99%
See 1 more Smart Citation
“…Russian researchers 143 have developed an ETAAS instrument with two vaporization zones for the simultaneous determination of Cd, Hg and Pb in sea and river waters.…”
Section: Atomic Absorption Spectrometrymentioning
confidence: 99%
“…The simplified chemical separation employs mainly HCl as the eluting reagent, resulting in rapid purification in three working days. The same Chinese research group381 demonstrated precise and accurate measurements of143 Nd/144 Nd without separating Nd from Sm.Instrumental mass discrimination was corrected using146 Nd/144 Nd as an internal standard, after correction of the isobaric interference of144 Sm on144 Nd using interference-free147 Sm/149 Sm for mass fractionation. Their data indicated that the mass discrimination of Sm and Nd was not the same and varied during an analytical session, hence the need to calculate mass biases for each element on individual samples.Martin et al…”