2008
DOI: 10.1541/ieejpes.128.1439
|View full text |Cite
|
Sign up to set email alerts
|

72kV低圧力ドライエア絶縁C-GISにおけるドライエア中および真空中での絶縁技術

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
5
0

Year Published

2009
2009
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(5 citation statements)
references
References 4 publications
0
5
0
Order By: Relevance
“…Relying on the good insulation performance of air, the air insulated switchgears (AIS) are widely applied in lowand medium-voltage electrical substations to avoid the partial discharge [1]. When the insulation defects such as overload and overheat occur, the AIS can quickly switch off the current thus ensuring the safety operation for the whole power system [2,3]. However, the long term partial discharge can largely impair the insulation performance of the AIS, even causing it breakdown and threating the safety operation of the whole power system [4].…”
Section: Introductionmentioning
confidence: 99%
“…Relying on the good insulation performance of air, the air insulated switchgears (AIS) are widely applied in lowand medium-voltage electrical substations to avoid the partial discharge [1]. When the insulation defects such as overload and overheat occur, the AIS can quickly switch off the current thus ensuring the safety operation for the whole power system [2,3]. However, the long term partial discharge can largely impair the insulation performance of the AIS, even causing it breakdown and threating the safety operation of the whole power system [4].…”
Section: Introductionmentioning
confidence: 99%
“…Air-insulated switchgear is an important type of high-voltage electrical equipment, mainly applied to protect and control the equipment in the power system, such as transformers, generators, capacitors, and cables, to ensure the safety and normal operation of the whole power system. 1 In air-insulated switchgears, the air is used as the insulation medium to prevent partial discharge in the equipment, therefore, they are tremendously applied in medium and low-voltage power equipment owing to their unique merits of low cost and good performance. 2 However, after a long time running, some inevitable insulation defects, including partial discharge and electric corona, would occur in such kind of equipment, decomposing the air into two toxic gas species, including NO 2 and O 3 , 2,3 wherein the partial overheat can facilitate such process dramatically.…”
Section: Introductionmentioning
confidence: 99%
“…In the power system, the ring main unit is the widely applied equipment for electric transmission and distribution, with the advantages of simple operation, small size, and low cost. , From another aspect, safe operation plays a critical role in ensuring the safety and stability of the whole power system. When insulation defects such as partial discharge and partial overheat occur, the air in the ring main unit would be decomposed into several impurity gases wherein O 3 and NO 2 are the main species. , As reported, the presence of these decomposed species would impair the insulation behavior of the filled air, thus weakening the operation status of the ring main unit .…”
Section: Introductionmentioning
confidence: 99%