2006
DOI: 10.1016/j.spinee.2006.06.143
|View full text |Cite
|
Sign up to set email alerts
|

9:37114. S-B Charité versus ProDisc: A Comparative Study of Minimum 3-Year Follow-Up

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
52
1
3

Year Published

2007
2007
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 40 publications
(58 citation statements)
references
References 0 publications
2
52
1
3
Order By: Relevance
“…The TDR group appeared to reach maximum improvement at 1 year indicating that the TDR group improved more rapidly than the fusion group (Fig. 1), which is in accordance with the findings of others [22]. Whether this difference is a positive effect of preserved motion in the segment, the total excision of the pain source (disc), or a negative effect of the surgical approach in the fusion group remains unclear.…”
Section: Discussionsupporting
confidence: 88%
“…The TDR group appeared to reach maximum improvement at 1 year indicating that the TDR group improved more rapidly than the fusion group (Fig. 1), which is in accordance with the findings of others [22]. Whether this difference is a positive effect of preserved motion in the segment, the total excision of the pain source (disc), or a negative effect of the surgical approach in the fusion group remains unclear.…”
Section: Discussionsupporting
confidence: 88%
“…"SKIPPED" LEVEL DISC DEGENERATIONbody arthroplasty techniques were used to facilitate, in premise, motion preservation (42,44,45). In fact, using such a model for reference may be more appropriate, because, as some investigators contend, the escalating severity of disc degeneration has been associated with an increase in segmental motion (37,38).…”
Section: Discussionmentioning
confidence: 99%
“…The authors suggested that there was not only an absence of facet joint degeneration but also possibly a reversal of an already existing facet osteoarthritis which was referred to as ''improved segmental kinematics and restored intervertebral disc space height with consecutive unloading of the facet joints''. Conversely, however, Shim et al [56] in a recent retrospective comparative study between ProDisc and Charité reported a high progression rate of facet joint osteoarthritis for both types of prosthesis in 32-36.4% of all patients. According to the authors, this high incidence of facet degeneration after an average FU of only 38-41 months seemed to be too short to be explained by the natural course of degeneration.…”
Section: Discussionmentioning
confidence: 92%