1997
DOI: 10.1016/s0168-9002(96)01234-x
|View full text |Cite
|
Sign up to set email alerts
|

A 16 × 16 pixel array detector for protein crystallography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

1998
1998
2003
2003

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 4 publications
0
4
0
Order By: Relevance
“…The most promising detector type for this application are single-photon-counting pixel detectors (Bro È nnimann et al, 2000). They provide a large dynamic range, high rate capability, low noise performance, very fast data readout, suf®cient spatial resolution and can be assembled to large area detectors (Barna et al, 1995;Beauville et al, 1997;Fischer et al, 1999). A 2k  2k system with 200 mm  200 mm pixels is under development at the SLS.…”
Section: Introductionmentioning
confidence: 99%
“…The most promising detector type for this application are single-photon-counting pixel detectors (Bro È nnimann et al, 2000). They provide a large dynamic range, high rate capability, low noise performance, very fast data readout, suf®cient spatial resolution and can be assembled to large area detectors (Barna et al, 1995;Beauville et al, 1997;Fischer et al, 1999). A 2k  2k system with 200 mm  200 mm pixels is under development at the SLS.…”
Section: Introductionmentioning
confidence: 99%
“…The same readout electronics associated with a histogramming memory to build up the distribution of counts recorded by each pixel in a fixed time interval is employed in imaging applications. In either case, only the presence of a signal is recorded by the readout system [1]- [4]. There are, however, situations where signal-related parameters are to be extracted and a readout that is able to acquire and process multiparametric information is required.…”
Section: Introductionmentioning
confidence: 99%
“…7 as a function of the charge injected at the input by a delta-impulse. The plot of fig.7 shows that the noise-induced dispersion of the triggering instant remains almost constant as soon as the input charge exceeds 2x10 4 electrons. This indirectly proofs that the slope at the crossover point in the signal presented at the zero crossing discriminator has a high degree of independence from the value of the injected charge.…”
Section: Circuit Behaviormentioning
confidence: 94%
“…The same readout electronics associated with a histogramming memory to build-up the distribution of counts recorded by each pixel in a fixed time interval is employed in imaging applications. In either case, only the presence of a signal is recorded by the readout system [1], [2], [3], [4].…”
Section: Introductionmentioning
confidence: 99%