2003
DOI: 10.1109/lpel.2004.825561
|View full text |Cite
|
Sign up to set email alerts
|

A 3-D space vector modulation generalized algorithm for multilevel converters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
69
0

Year Published

2007
2007
2018
2018

Publication Types

Select...
4
3
2

Relationship

0
9

Authors

Journals

citations
Cited by 97 publications
(69 citation statements)
references
References 5 publications
0
69
0
Order By: Relevance
“…1 together with the proposed voltage balance controller have been implemented and executed under PSCAD environment. The modulation strategy introduced to generate the gating signals of the converter is the space vector modulation presented in [46]. The values of the system parameters considered in the simulation are summarized in Table 2.…”
Section: Simulation Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…1 together with the proposed voltage balance controller have been implemented and executed under PSCAD environment. The modulation strategy introduced to generate the gating signals of the converter is the space vector modulation presented in [46]. The values of the system parameters considered in the simulation are summarized in Table 2.…”
Section: Simulation Resultsmentioning
confidence: 99%
“…Besides, the same system parameters described in Table 2 as well as the modulation strategy considered in the previous section have been used in the experiments. It is worth noticing that due to the low computational cost of the modulation strategy considered [46], there is no need of special software optimization of the controllers, so they can be directly implemented in the system.…”
Section: Experimental Verificationmentioning
confidence: 99%
“…In the industry, it usually uses the following three methods: sinusoidal-triangular carrier modulation [2][3][4], space vector modulation combined with three-dimensional algorithm [5][6][7], the specific harmonic elimination method [8][9][10].It has the following characteristics: power switching devices bear the voltage stress is small; It requires a large number of clamp diodes while clamping the use of diodes to increase the total loss, reducing the conversion efficiency; There is a problem of DC capacitor voltage imbalance; It is difficult to ensure of the capacitor pressure the DC side; Its circuit structure is simple; It is more used in the UPS and photovoltaic inverter; It is mainly 3-level circuit, generally not more than five levels.…”
Section: Figure I Diode-clamped 3-level Topologymentioning
confidence: 99%
“…For example; the node that has the switching pattern (3,0,-1) means that the H-Bridges in phase a generates +3V, in phase b generates 0V and in phase c generates -V. The same output voltage of the inverter can be generated by other switching patterns for example (2,-1,-2) and (1,-2,-3). Many methods proposed in using space vector modulation of multilevel inverter [11,12,13].The method that is adopted in this work is proposed in [11], as it has the following feature:  It is very simple and effective.  The output voltage contains minimum distortion.…”
Section: Space Vector Modulation For 7-level Invertermentioning
confidence: 99%