A 3D kinematic estimation of knee prosthesis using X-ray projection images: clinical assessment of the improved algorithm for fluoroscopy images

Abstract: In this paper, we propose three ideas to improve a kinematic estimation algorithm for total knee arthroplasty. The first is a two-step estimation algorithm that improves estimation accuracy by excluding certain assumptions needed for the pattern matching algorithm reported by Banks and Hodge. The second is incorporating a 3D geometric articulation model into the algorithm to improve estimation accuracy substantially for the depth translation, and to introduce contact points' trajectories between the articular … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2011
2011
2018
2018

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 19 publications
(10 citation statements)
references
References 19 publications
0
10
0
Order By: Relevance
“…2i) views of the components were helpful in determining a reasonable range of medial-lateral translation between the two components. Out-ofplane position estimates can be significantly improved using collision detection, which involves ensuring that the femoral component does not intersect with the polyethylene tibial insert (Hirokawa et al, 2008;Prins et al, 2010). The pose of the insert can be determined based on the tibial tray pose if a fixed bearing implant is used or based on beads embedded in the insert (Fantozzi et al, 2004).…”
Section: Differencementioning
confidence: 99%
“…2i) views of the components were helpful in determining a reasonable range of medial-lateral translation between the two components. Out-ofplane position estimates can be significantly improved using collision detection, which involves ensuring that the femoral component does not intersect with the polyethylene tibial insert (Hirokawa et al, 2008;Prins et al, 2010). The pose of the insert can be determined based on the tibial tray pose if a fixed bearing implant is used or based on beads embedded in the insert (Fantozzi et al, 2004).…”
Section: Differencementioning
confidence: 99%
“…However, the RSA application has recently been extended to identify the relative pose (using X-ray) or the moving trajectory of prostheses (using fluoroscopy; Selvik, 1989;Banks and Hodge, 1996;Hoff et al, 1998;Kaptein et al, 2004;Valstar et al, 2005;Bingham and Li, 2006;Hanson et al, 2006;Hirokawa et al, 2008). Historically, the RSA technique can be divided into marker-and model-based techniques.…”
Section: Introductionmentioning
confidence: 99%
“…If the projected images of femoral and tibial prostheses are overlapped with each other, it is more difficult for the clinician to evaluate the prosthetic misalignment and wear (Fig. 1b) [4,6,9,12,13,26].…”
Section: Introductionmentioning
confidence: 99%