2012 IEEE Radio Frequency Integrated Circuits Symposium 2012
DOI: 10.1109/rfic.2012.6242288
|View full text |Cite
|
Sign up to set email alerts
|

A 52–66GHz subharmonically injection-locked quadrature oscillator with 10GHz locking range in 40nm LP CMOS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 16 publications
(16 citation statements)
references
References 6 publications
0
16
0
Order By: Relevance
“…4, is finally chosen to be around 0.45 in our work, thus a continuous tuning range is achieved and the resonant impedances at both modes are roughly equal and both are boosted compared with that of the conventional LC resonators. Now the oscillation condition can be derived using the expressions of the effective [see (13), (14), (16), and (17)] and the expressions of the resonant impedance [see (18) and (19)]. When the proposed VCO works at the even mode, the effective should be strong enough to compensate the energy loss of the resonator at the even-mode resonant frequency.…”
Section: B Oscillation Conditionmentioning
confidence: 99%
“…4, is finally chosen to be around 0.45 in our work, thus a continuous tuning range is achieved and the resonant impedances at both modes are roughly equal and both are boosted compared with that of the conventional LC resonators. Now the oscillation condition can be derived using the expressions of the effective [see (13), (14), (16), and (17)] and the expressions of the resonant impedance [see (18) and (19)]. When the proposed VCO works at the even mode, the effective should be strong enough to compensate the energy loss of the resonator at the even-mode resonant frequency.…”
Section: B Oscillation Conditionmentioning
confidence: 99%
“…Three kinds of resonators are used for the mm-wave LC-tank ILO: a single-LC tank [4] [7], a single-LC tank with a lowered [6], and a coupled-LC tank [9]. A comparison of these three approaches, in terms of published solutions, is available in [9].…”
Section: Comparison With Single-lc-tank Approachmentioning
confidence: 99%
“…A comparison of these three approaches, in terms of published solutions, is available in [9]. These three approaches are theoretically compared in Fig.…”
Section: Comparison With Single-lc-tank Approachmentioning
confidence: 99%
See 2 more Smart Citations