2005
DOI: 10.1107/s0909049505020959
|View full text |Cite
|
Sign up to set email alerts
|

A beamline for high-pressure studies at the Advanced Light Source with a superconducting bending magnet as the source

Abstract: SynopsisA new high-pressure facility for diffraction and spectroscopy using diamond anvil highpressure cells has been developed at the Advanced Light Source. Details of the mechanics and performance of the beamline and endstation will be given. AbstractA new facility for high-pressure diffraction and spectroscopy using diamond anvil highpressure cells has been built at the Advanced Light Source on Beamline 12.2.2. This beamline benefits from the hard X-radiation generated by a 6 Tesla superconducting bending m… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

2
96
0

Year Published

2007
2007
2024
2024

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 146 publications
(98 citation statements)
references
References 14 publications
2
96
0
Order By: Relevance
“…When determining pressure using the ruby manometer, the 488nm excitation laser fluence and exposure time were minimized in order to inhibit photo-conversion to grey phosphorus. Data were collected on beamline 12.2.2 at the Advanced Light Source [12,13]. This beamline is equipped with a set of brightness preserving optics that delivers about 2 x 10 10 photons per second into a 10µm focal spot.…”
Section: Methodsmentioning
confidence: 99%
“…When determining pressure using the ruby manometer, the 488nm excitation laser fluence and exposure time were minimized in order to inhibit photo-conversion to grey phosphorus. Data were collected on beamline 12.2.2 at the Advanced Light Source [12,13]. This beamline is equipped with a set of brightness preserving optics that delivers about 2 x 10 10 photons per second into a 10µm focal spot.…”
Section: Methodsmentioning
confidence: 99%
“…Details on the source and optics of beamline 12.2.2 at ALS are given elsewhere 12 . For the present experiment, the X-ray beam was refocused from its primary focal spot of ~150 µm (h)…”
Section: Experimental Procedurementioning
confidence: 99%
“…The procedure to center the sample onto the rotation axis and accurately determine the sample to detector distance is described in Ref. 12. The sample to detector distance was calibrated using a LaB 6 standard with fitting routines as implemented in Fit2d…”
Section: Experimental Procedurementioning
confidence: 99%
“…31,32 A setup for single-sided in-situ laser heating of a DAC in radial diffraction geometry was recently implemented on this beamline. 5 In order to remotely change pressure, we constructed an rDAC holding frame which is compatible with various radial diffraction cells.…”
Section: Experimental Techniquementioning
confidence: 99%
“…31 Sample to detector distance and detector non-orthognality were calibrated using a LaB 6 standard. For run 1 at ambient temperature no pressure calibrant was used and pressure was calibrated with a 3 rd order Birch-Murnaghan equation of state for bcc Fe and hcp Fe.…”
Section: Experimental Techniquementioning
confidence: 99%