2000
DOI: 10.1016/s0304-3991(99)00123-0
|View full text |Cite
|
Sign up to set email alerts
|

A cantilever array-based artificial nose

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
203
1
1

Year Published

2000
2000
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 332 publications
(205 citation statements)
references
References 30 publications
0
203
1
1
Order By: Relevance
“…Various techniques, such as atomic force microscope cantilever arrays, have been suggested for this purpose. Baller et al (2000) used a microfabricated array of silicon cantilevers for the detection of vapours. Each of the cantilevers was coated with a specific sensor layer to transduce a physical process or a chemical reaction into a nanomechanical response.…”
Section: (I ) Spiderwebmentioning
confidence: 99%
“…Various techniques, such as atomic force microscope cantilever arrays, have been suggested for this purpose. Baller et al (2000) used a microfabricated array of silicon cantilevers for the detection of vapours. Each of the cantilevers was coated with a specific sensor layer to transduce a physical process or a chemical reaction into a nanomechanical response.…”
Section: (I ) Spiderwebmentioning
confidence: 99%
“…Although most studies use the data from one or more sensor can tilevers, the possibility to produce thousands of cantilevers on a single Используя восьмикантилеверный датчик с кон солями, покрытыми различными полимерами, авторы [8] показали возможность различать в воз духе "запахи" различных спиртов.…”
Section: Applications Of Biosensors Depending On Types Of Integrationunclassified
“…"Electronic nose" based on arrays of cantilever sensors can be used for environmental monitoring. Using an eight cantilever sensor with can tilevers coated with different poly mers, the authors of [8] showed the possibility to distinguish in the air "smells" of different alcohols.…”
Section: Applications Of Biosensors Depending On Types Of Integrationmentioning
confidence: 99%
“…For example, electron beam lithography can be used to write submicrometer and nanoscale metal patterns on the end of AFM tips for magnetic and thermal imaging (40). Gerber, Gimzewski, and colleagues have produced arrays of cantilevers on one probe body for electronic nose applications (41). Probes consisting of eight linearly arranged cantilevers, each coated with a different polymeric sensor layer, enable the identification of up to eight different chemical species.…”
Section: Microfabricationmentioning
confidence: 99%