2021
DOI: 10.1016/j.tcr.2021.100544
|View full text |Cite
|
Sign up to set email alerts
|

A case report of extensive segmental defect of the humerus due to thermal necrosis treated with Masquelet technique

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
3
1

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 11 publications
0
4
0
Order By: Relevance
“…5 The IMT has demonstrated successful results for defects ranging from 5 to 24 cm and in both upper and lower extremity defects for septic and aseptic nonunions. 6,7,14–19 In this case, the patient did not return for a second bone grafting procedure until 8 weeks after her first stage IMT to fully eradicate her infection. This is on the tail end of what has been described as the optimal bone grafting window and may have had an effect on the healing potential of her bone graft because she did require a secondary bone graft procedure to achieve union.…”
Section: Discussionmentioning
confidence: 97%
“…5 The IMT has demonstrated successful results for defects ranging from 5 to 24 cm and in both upper and lower extremity defects for septic and aseptic nonunions. 6,7,14–19 In this case, the patient did not return for a second bone grafting procedure until 8 weeks after her first stage IMT to fully eradicate her infection. This is on the tail end of what has been described as the optimal bone grafting window and may have had an effect on the healing potential of her bone graft because she did require a secondary bone graft procedure to achieve union.…”
Section: Discussionmentioning
confidence: 97%
“…The use of fixation devices has shown some major drawbacks, such as infection and immune responses, bone adsorption, stress shielding, osteoporosis, and the need for a second surgery to remove the implanted devices (e.g., orthopedic screw) after bone healing 4 . Bone cement was also an inadequate option due to its low porosity and compact structure, which impelled the bone parts toward death 5 . Segmental bone tissue engineering is a novel approach to the regeneration of large bone defects 6 .…”
Section: Introductionmentioning
confidence: 99%
“…4 Bone cement was also an inadequate option due to its low porosity and compact structure, which impelled the bone parts toward death. 5 Segmental bone tissue engineering is a novel approach to the regeneration of large bone defects. 6 The size of the scaffolds is a key factor that directly affects cell migration and viability.…”
Section: Introductionmentioning
confidence: 99%
“…The use of xation devices has shown some major drawbacks, such as infection and immune responses, bone adsorption, and stress shielding, osteoporosis, and the need for a second surgery to remove the implanted devices (e.g., orthopedic screw) after bone healing (Moghaddam, Andani et al 2016). Bone cement was also an inadequate option due to its low porosity and compact structure, which impelled the bone parts towards death (Mukhopadhaya, Gautam et al 2021). Segmental bone tissue engineering is a novel approach to the regeneration of large bone defects (Alkindi, Ramalingam et al 2021).…”
Section: Introductionmentioning
confidence: 99%