2010
DOI: 10.1016/j.jhsa.2009.12.026
|View full text |Cite
|
Sign up to set email alerts
|

A Cemented Surface Replacement Prosthesis in the Basal Thumb Joint

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
17
0

Year Published

2010
2010
2024
2024

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 23 publications
(17 citation statements)
references
References 46 publications
0
17
0
Order By: Relevance
“…A common theme in studies in which a Kirschner wire was used after the surgical procedure [3,6,14,15] was that patients were casted or splinted at least until the wire was removed, which occurred 4 to 5 weeks after surgery. For the studies in which some sort of joint prosthesis was implanted [1,9,18,20,21,24], postoperative immobilization time ranged from 2 to 6 weeks. The type of immobilization used for the studies was described in varying detail.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…A common theme in studies in which a Kirschner wire was used after the surgical procedure [3,6,14,15] was that patients were casted or splinted at least until the wire was removed, which occurred 4 to 5 weeks after surgery. For the studies in which some sort of joint prosthesis was implanted [1,9,18,20,21,24], postoperative immobilization time ranged from 2 to 6 weeks. The type of immobilization used for the studies was described in varying detail.…”
Section: Resultsmentioning
confidence: 99%
“…Some patients simply were shown exercises after the immobilization was discontinued [2,5,8,12,13,15,19]. Patients in other studies were referred to a therapist after the period of immobilization [1,3,4,7,9,24]. Finally, some patients were only referred to a therapist if it was felt they were not making satisfactory progress during followup visits [6,14,21,22].…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…These implants have been developed to limit the problem of loosening associated with total joint arthroplasty. 25 The Avanta SR TMC prosthesis (Fig. 3) is a cemented total surface replacement implant consisting of two saddle-shaped components to mimic the joint contour.…”
Section: Surface Replacementmentioning
confidence: 99%
“…The trapezium is resurfaced with a chrome-cobalt alloy with a rounded peg for anchorage in the center of the carpal bone. 25 In a cadaveric study, Imaeda and colleagues 26 showed that resection arthroplasty and ball-andsocket joint replacements alter the normal kinematics of the thumb, thereby changing the musculotendinous moment arms and altering force transmission. Using a cadaveric model, Uchiyama and colleagues 10 showed the total joint surface replacement had similar kinematics and stability to the normal trapeziometacarpal joint, provided that a normal ligament tension was present.…”
Section: Surface Replacementmentioning
confidence: 99%