1998
DOI: 10.1016/s0925-4005(98)00106-3
|View full text |Cite
|
Sign up to set email alerts
|

A chemical micro analysis system for the measurement of pressure, flow rate, temperature, conductivity, UV-absorption and fluorescence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
26
0

Year Published

1999
1999
2015
2015

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 38 publications
(26 citation statements)
references
References 7 publications
0
26
0
Order By: Relevance
“…Early flow-sensor construction attempts included miniaturization of well-established macroflow sensing principles and their application to m-TAS. In most instances, the flow sensors were in physical contact with the media to envisage the flow [141][142][143][144][145]. Others utilized heat transfer flow measurements by gas flow or a TOF-type measurement with a locally initiated temperature pulse [142,143].…”
Section: Flow Measurementmentioning
confidence: 99%
See 1 more Smart Citation
“…Early flow-sensor construction attempts included miniaturization of well-established macroflow sensing principles and their application to m-TAS. In most instances, the flow sensors were in physical contact with the media to envisage the flow [141][142][143][144][145]. Others utilized heat transfer flow measurements by gas flow or a TOF-type measurement with a locally initiated temperature pulse [142,143].…”
Section: Flow Measurementmentioning
confidence: 99%
“…In most instances, the flow sensors were in physical contact with the media to envisage the flow [141][142][143][144][145]. Others utilized heat transfer flow measurements by gas flow or a TOF-type measurement with a locally initiated temperature pulse [142,143]. Another type of sensor was based on pressure drop measurement over a well-characterized hydraulic resistance [141].…”
Section: Flow Measurementmentioning
confidence: 99%
“…In any case, it is important to select an optimum sensor depending on the substance for measure. Research is being carried out to integrate many different types of microsensors into a microflow cell by micromachining [31].…”
Section: Detection Methodsmentioning
confidence: 99%
“…Typical measuring parameters are pH value, ion‐ and analyte concentration, electrolyte conductivity, temperature, etc. . Often, these sensor arrays integrate a large number of single‐function sensors, which are based on different transducer structures and a variety of sensitive materials .…”
Section: Introductionmentioning
confidence: 99%