2020
DOI: 10.1080/09540105.2020.1736010
|View full text |Cite|
|
Sign up to set email alerts
|

A colloidal gold immunochromatography test strip based on a monoclonal antibody for the rapid detection of triadimefon and triadimenol in foods

Abstract: In this study, we produced a specific monoclonal antibody (mAb) against triadimefon (TDF) and triadimenol (TDN). The half-maximal inhibitory concentration for TDF and TDN was 5.25 and 9.98 ng/ mL, respectively, with a linear detection range (IC 20-IC 80) of 1.09-25.35 and 2.29-43.61 ng/mL, respectively. Subsequently, we developed a colloidal gold immunochromatography test strip for the analysis of TDF and TDN in tomato. The results obtained from the colloidal gold immunochromatography test strip were in accord… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
8
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
8

Relationship

2
6

Authors

Journals

citations
Cited by 18 publications
(8 citation statements)
references
References 31 publications
0
8
0
Order By: Relevance
“…Finally, 50 μL/well of the 0.01 M H 2 SO 4 solution was used to stop the color reaction, and the absorbance was measured at 450 nm using a microplate reader. 25,26 Several parameters can affect the performance and sensitivity of the ic-ELISA, and this study optimized two of the important terms of the working solution, namely, pH and ionic strength. 27−29 A series of standard dilution buffers at different pH values (pH 4.0, 5.5, 7.4, 8.8, and 9.6) were used to dilute the imidocarb standards.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Finally, 50 μL/well of the 0.01 M H 2 SO 4 solution was used to stop the color reaction, and the absorbance was measured at 450 nm using a microplate reader. 25,26 Several parameters can affect the performance and sensitivity of the ic-ELISA, and this study optimized two of the important terms of the working solution, namely, pH and ionic strength. 27−29 A series of standard dilution buffers at different pH values (pH 4.0, 5.5, 7.4, 8.8, and 9.6) were used to dilute the imidocarb standards.…”
Section: Discussionmentioning
confidence: 99%
“…After one more washing step, 100 μL/well of the TMB/peroxide-based substrate solution was added by incubation at 37 °C for 15 min. Finally, 50 μL/well of the 0.01 M H 2 SO 4 solution was used to stop the color reaction, and the absorbance was measured at 450 nm using a microplate reader. , …”
Section: Methodsmentioning
confidence: 99%
“…After vortexing, the sample was centrifuged at 6500 r/min for 15 min, and the supernatant was removed. The pH of the supernatant was adjusted to 7.4 with 0.75 M sodium hydroxide [ 28 ]. Five instances of dilution with HBS were used to obtain the final sample extract.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, the gold nanoparticles produced by shorter and cheaper procedures are still one of the most widely used materials today in various fields. 40–42…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, the gold nanoparticles produced by shorter and cheaper procedures are still one of the most widely used materials today in various elds. [40][41][42] Colloidal Au spheres (AuSPs) are a certain type of gold particles produced aer various reducing agents acting on chloroauric acid, and they exhibit a stable colloidal state in solvents. 43,44 AuSPs are widely used due to their easy synthesis, low cost, and good chemical stability.…”
Section: Introductionmentioning
confidence: 99%