1992
DOI: 10.1063/1.1142554
|View full text |Cite
|
Sign up to set email alerts
|

A combined Thomson–Rayleigh scattering diagnostic using an intensified photodiode array

Abstract: A combined Thomson-Rayleigh scattering device is discussed. It consists of a Nd:YAG laser as a light source in combination with a multichannel detection technique consisting of a gated light amplifier in combination with an optical multichannel analyzer. Special attention is focused on the analysis of the measured spectra. Including convolution methods and taking into account weak coherent effects increases the dynamic range and the accuracy of the measured electron density n, and temperature T, and neutral pa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

5
94
0

Year Published

1994
1994
2013
2013

Publication Types

Select...
5
2
1

Relationship

1
7

Authors

Journals

citations
Cited by 115 publications
(99 citation statements)
references
References 25 publications
5
94
0
Order By: Relevance
“…The n +/s + ratio turns out to be of the right order of magnitude [compare the outcome of Eq. (5) to Fig. 9 13.…”
Section: A Thomson-rayleigh Scattering Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The n +/s + ratio turns out to be of the right order of magnitude [compare the outcome of Eq. (5) to Fig. 9 13.…”
Section: A Thomson-rayleigh Scattering Resultsmentioning
confidence: 99%
“…The arc channel has a diameter of 4 mm. The are produces a thermal plasma at subatmospheric pressure, characterized by a relatively high heavy particle temperature (Tt, =T, =l eV) and high electron densities (10 -10 m Figure 2 shows the combined Thomson-Rayleigh diagnostic, which is described in detail elsewhere [5]. The Usually, every lateral scan consists of 80 measurements, covering a lateral range of 100 mm.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…[4] for an extended description of the device), currently under constructions at FOM Rijnhuizen, The Netherlands, will employ a high-pressure cascaded arc source [5]. A prototype of the source has successfully been tested at the Pilot-PSI machine [6], the forerunner of MAGNUM-PSI and proved the plasma parameters anticipated for MAGNUM-PSI and listed in Table 2.…”
Section: Magnum-psimentioning
confidence: 99%
“…a plasma with high density and low temperature with hydrogen/deuterium as a process gas. The choice was made to use a highpressure plasma source, the so-called cascaded arc source [15], which typically operates at pressures around 10 4 Pa, which is to be compared with the pressure of a few Pa in typical LaB 6 assisted arc discharges [3].…”
Section: Design Criteriamentioning
confidence: 99%