2016 2nd International Conference on Control, Instrumentation, Energy &Amp; Communication (CIEC) 2016
DOI: 10.1109/ciec.2016.7513777
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study between different modulations techniques used in field oriented control induction motor drive

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
3
2
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 12 publications
0
7
0
Order By: Relevance
“…Discretization of voltage has a negative impact that is, an imperceptible amount of subharmonics is generated while synthesizing the periodic waveforms [113,114]. In order to obtain an indistinguishable output, DM-CC should be switched at a seven times higher frequency compared to PWM modulator [113,115].…”
Section: 1 Discrete Modulation Current Controller (Dm-cc)mentioning
confidence: 99%
See 1 more Smart Citation
“…Discretization of voltage has a negative impact that is, an imperceptible amount of subharmonics is generated while synthesizing the periodic waveforms [113,114]. In order to obtain an indistinguishable output, DM-CC should be switched at a seven times higher frequency compared to PWM modulator [113,115].…”
Section: 1 Discrete Modulation Current Controller (Dm-cc)mentioning
confidence: 99%
“…Primarily, the fuzzy logic controller is utilized as a replacement for the conventional proportional and integral controller [114], [118]. The principal block diagram of a fuzzy-tuned PI controller, together with the fuzzy inference system is shown in Fig.…”
Section: Fuzzy Logic (Fl) Based Current Controllermentioning
confidence: 99%
“…In case the reference control signal is the voltage signals, the Pulse Width Modulation (PWM) method can be used to produce the switching pulse to control the inverter. In case this signal is current, the hysteresis current control method can be used for generating the switching pulses [13,14]. Although the current of IMD applying HC method is high ripple, however, due to its simple structure, low switching losses, and fast response, the HC method is preferred in practice [15,16].…”
Section: Introductionmentioning
confidence: 99%
“…Therefore, determining the rotor flux angle is extremely important in the FOC method with the HC controller. A typical FOC applied for HC controller with the flux angle calculating form integral algorithm is presented in [13,17,18]. The simulation results have demonstrated the effectiveness of this method.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation