2008
DOI: 10.2116/analsci.24.669
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Study of AgX (X = Cl−, Br−, I− and N3−) Solid-Phase Reactors for Flow-Injection Determination of Cyanide in Electroplating Wastewater

Abstract: In this study, a rapid flow injection-flame atomic absorption spectrometry for cyanide detection was developed. Different AgX (where X is Cl -, Br -, I -and N3 -) solid-phase reagents (SPR) were tested for indirect determination of cyanide. In a single-line FIA system, the cyanide was allowed to react with AgX SPR, which in turn changed Ag ions in AgX to silver cyanide complexes in a sodium hydroxide carrier stream. The eluent containing the analyte as silver cyanide complexes was measured by FAAS. The calibra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
12
0
1

Year Published

2009
2009
2019
2019

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 11 publications
(13 citation statements)
references
References 31 publications
0
12
0
1
Order By: Relevance
“…Various analytical methods have been proposed for the determination of copper at low concentration levels. Most of them are photometric methods, flame atomic absorption spectroscopy, graphite furnace atomic absorption spectroscopy, inductively coupled plasma emission spectrometry and voltammetry . A variety of reagents have been used for constructing copper optodes.…”
Section: Introductionmentioning
confidence: 99%
“…Various analytical methods have been proposed for the determination of copper at low concentration levels. Most of them are photometric methods, flame atomic absorption spectroscopy, graphite furnace atomic absorption spectroscopy, inductively coupled plasma emission spectrometry and voltammetry . A variety of reagents have been used for constructing copper optodes.…”
Section: Introductionmentioning
confidence: 99%
“…A large number of analytical methods have been published concerning the determination of cyanide in water and wastewaters including ion-selective potentiometry [5], indirect atomic absorption spectrometry [6][7][8][9], spectrofluorimetry [10,11], molecular absorption spectrophotometry [12], chromatographic technique [13] and capillary electrophoresis [14]. There are numerous methods for determination of cyanide in the water and wastewater samples [15].…”
Section: Introductionmentioning
confidence: 99%
“…Our research group previously published some new methods for determination of cyanide using flow injection analysis-flame atomic absorption spectrometry (FIA-FAAS) by solid-phase reagents (SPR) such as MCO 3 (M = Cd, Zn), Ag 2 X (X ¼ SO 2À 3 , Cr 2 O 2À 7 , C 2 O 2À 4 and CO 2À 3 ) and AgX (X = Cl À , Br À , I À and N 3 À ) [29][30][31][32]. The best detection limit was obtained 1.92 Â 10 À6 mol L À1 .…”
Section: Introductionmentioning
confidence: 99%