2014
DOI: 10.1016/j.electacta.2014.08.072
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study of alkylimidazolium room temperature ionic liquids with FSI and TFSI anions near charged electrodes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

11
65
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6
4

Relationship

1
9

Authors

Journals

citations
Cited by 58 publications
(76 citation statements)
references
References 107 publications
11
65
0
Order By: Relevance
“…3 [37], the adsorption of coordinated Li + (either with two anions or partially dissociated with one TFSI anion) causes an increase in TFSI anion concentration at the electrode surface that may facilitate its breakdown (reduction). In the case of a pure ionic liquid, the adjacent layer is composed almost solely of large cations [38] which block access to the electrode for the TFSI anions. The reduction process is thus suppressed and no reduction peak is visible.…”
Section: Resultsmentioning
confidence: 99%
“…3 [37], the adsorption of coordinated Li + (either with two anions or partially dissociated with one TFSI anion) causes an increase in TFSI anion concentration at the electrode surface that may facilitate its breakdown (reduction). In the case of a pure ionic liquid, the adjacent layer is composed almost solely of large cations [38] which block access to the electrode for the TFSI anions. The reduction process is thus suppressed and no reduction peak is visible.…”
Section: Resultsmentioning
confidence: 99%
“…Rough edges provide dual beneficial effect. On the one hand, they enhance the EDL capacitance via the classical effect of surface roughness when their roughness dimensions are similar to the ions' sizes, as shown in references [7,12,93], and on the other hand, the electronic structure of the zigzag rough edges allows them to behave essentially as conductors. Furthermore, the rough edges have an advantage of increasing (almost doubling) the capacitance in the subnanometer pores as compared to smooth surface pores of similar widths [102].…”
Section: Discussionmentioning
confidence: 99%
“…The C d measured by EIS was confirmed to be equal to the zero-frequency (static) C d for the Hg|aqueous solution interface, 14 where the zero-frequency C d can be evaluated from electrocapillarity, i.e., potential dependence of interfacial tension. Theoretical and simulation studies such as mean field theory 3,33-35 and molecular dynamics (MD) simulations [36][37][38][39][40][41][42][43][44] always predict zero-frequency C d (capacitance in equilibrium) and the predicted and experimental zero-frequency C d could directly be compared and discussed if the latter is available. The ultraslow relaxation leads to deviation of the C d values obtained by EIS from the zero-frequency C d .…”
Section: Introductionmentioning
confidence: 99%