2006
DOI: 10.1016/j.electacta.2005.07.040
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study of Pb2+ selective sensors based on derivatized tetrapyrazole and calix[4]arene receptors

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
84
0

Year Published

2009
2009
2016
2016

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 284 publications
(85 citation statements)
references
References 28 publications
1
84
0
Order By: Relevance
“…Many efforts have been made to construct Pb(II) ISEs by using different organic and inorganic compounds (Srivastava et al 1995;Jain et al 2006, Chen et al 2006, Soleymanpour et al 2012Wardak 2011;Elmosallamy et al 2008;Li et al 2009;Michalska et al 2009;Kazemi et al 2009;Wilson et al 2010;Abbaspour et al 2010;Huang et al 2011;Zamani et al 2011;Yin et al 2012;Lisak et al 2012;Guzinski et al 2013). Very recently, the Rong et al (2012) reviewed the Pb(II) ISEs based on ionophores bearing oxygen/sulfur functional groups.…”
Section: Introductionmentioning
confidence: 99%
“…Many efforts have been made to construct Pb(II) ISEs by using different organic and inorganic compounds (Srivastava et al 1995;Jain et al 2006, Chen et al 2006, Soleymanpour et al 2012Wardak 2011;Elmosallamy et al 2008;Li et al 2009;Michalska et al 2009;Kazemi et al 2009;Wilson et al 2010;Abbaspour et al 2010;Huang et al 2011;Zamani et al 2011;Yin et al 2012;Lisak et al 2012;Guzinski et al 2013). Very recently, the Rong et al (2012) reviewed the Pb(II) ISEs based on ionophores bearing oxygen/sulfur functional groups.…”
Section: Introductionmentioning
confidence: 99%
“…Moreover, 500-fold Na + , K + , NO 3 − , 150-fold lactose, 100-fold urea, sucrose, Mg 2+ , SO 4 2− , Ca 2+ , 50-fold glucose, fructose, 5-fold ascorbic acid, histidine, aspartic acid, glycine, serine, 2-fold dopamine, threonine, valine, phenylalanine did not affect the determination of trp (<5 % of response current change). These results indicated good selectivity of the proposed electrode.…”
Section: Calibration Curvementioning
confidence: 99%
“…They prepared a lead ISE based on either diphenyltetrapyrazole and dipropoxycalix-4-arene derivatives [1], or based on tert-butylcalix-4-arene derivative [2]. In addition, they were synthesized iron and cobalt complexes of tetraazaporphyrin derivative and incorporated them into PVC matrix as ionophores to fabricate anion selective membrane electrodes which were responsive to azide and nitrite ions, respectively [3].…”
Section: Introductionmentioning
confidence: 99%