2022
DOI: 10.5109/4843121
|View full text |Cite
|
Sign up to set email alerts
|

A Comparative Study of Photovoltaic Water Pumping System-Driving Conventional AC Single-phase and Three-phase Motor Submersible Pumps

Abstract: The water is very important to human lives. The best and most appropriate way to have an adequate supply of water is to use solar energy to drive pumps instead of using fossil energy. This research was conducted as a comparative study of a conventional submersible AC motor-pump driven by a photovoltaic system using two types of AC motor which are single-phase and three-phase submersible water pumps. The performance of the system was measured according to the standard test procedure in IEC 62253: 2011 while the… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 13 publications
0
5
0
Order By: Relevance
“…Smaller PR calculations interval, such as weekly or daily, may be used to examine the frequency of component failures in large-scale commercial systems 29) . PR equation is obtained from the equation below 11,30) :…”
Section: Performance Ratio (Pr)mentioning
confidence: 99%
“…Smaller PR calculations interval, such as weekly or daily, may be used to examine the frequency of component failures in large-scale commercial systems 29) . PR equation is obtained from the equation below 11,30) :…”
Section: Performance Ratio (Pr)mentioning
confidence: 99%
“…The maximum efficiency of the motor pump is recorded to be 94%, and the minimum efficiency recorded is less than 19% after 3 pm. Figure 11 (b) represents the overall efficiency variation to the time of the day 37) . The overall efficiency is the multiplication of the SP and pumps efficiency.…”
Section: Experimental Test Rigmentioning
confidence: 99%
“…Another active cooling technique is water spray cooling on the PV panel. It reduced their temperature, increase the power generation, and enhance the system efficiency by approximately 12.5% 11) . Double active cooling techniques was applied to 20 W polycrystalline PV module.…”
Section: Introductionmentioning