A comparative study of the PIV and LDV measurements on a self-induced sloshing flow

Abstract: : Particle Imaging Velocimetry (PIV) and Laser Doppler Velocimetry (LDV) measurements on a self-induced sloshing flow in a rectangular tank had been conducted in the present study. The PIV measurement result was compared with LDV measurement result quantitatively in order to evaluate the accuracy level of the PIV measurement. The comparison results show that the PIV and LDV measurement results agree with each other well in general for both mean velocity and fluctuations of the velocity components. The average … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
11
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 32 publications
(12 citation statements)
references
References 6 publications
1
11
0
Order By: Relevance
“…Someya et al 6 and Saga et al 7 have studied a particular system where self-induced free-surface oscillations occurred. The liquid oscillations (which qualified as swell flapping) were the result of the interaction of a jet with the tank structure in the presence of a free surface.…”
Section: Introductionmentioning
confidence: 98%
“…Someya et al 6 and Saga et al 7 have studied a particular system where self-induced free-surface oscillations occurred. The liquid oscillations (which qualified as swell flapping) were the result of the interaction of a jet with the tank structure in the presence of a free surface.…”
Section: Introductionmentioning
confidence: 98%
“…This type of sloshing can be found in real-time applications such as liquid-oil carrier vehicles, space vehicles, and liquefied-natural-gas vessels in cargo ships. The fluid dynamic mechanism of the externally or selfinduced sloshing phenomenon should be understood clearly in order to attain an optimum safety design of the reactor vessels to prevent the occurrence of sloshing [2]. For example, in a liquidmetal fast-breeder reactor, the self-induced or externally induced sloshing of the high-temperature sodium coolant may occur in reactor vessels.…”
Section: Introductionmentioning
confidence: 99%
“…When using the optical instruments such as the LDV and PIV, the adjustment on the light beam or the piece of light sources could be arduous, and that demands keeping a good light transmission through the flow field, as well as seeding proper tracer particles in the flow field. The high price is another reason to limit the wide use of the LDV and PIV . So the traditional measurement technique, namely pressure probe technique, is necessary to be developed.…”
Section: Introductionmentioning
confidence: 99%
“…The high price is another reason to limit the wide use of the LDV and PIV. 5 So the traditional measurement technique, namely pressure probe technique, is necessary to be developed.…”
Section: Introductionmentioning
confidence: 99%