2005
DOI: 10.1002/aic.10653
|View full text |Cite
|
Sign up to set email alerts
|

A comparative study of UVP and LDA techniques for pulp suspensions in pipe flow

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
22
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
7
1

Relationship

3
5

Authors

Journals

citations
Cited by 34 publications
(22 citation statements)
references
References 41 publications
0
22
0
Order By: Relevance
“…The results of modeling the displacement of yoghurt by water were compared with experimental measurements of the velocity field and phase distribution [15]. The techniques used for the experimental measurements were ultrasonic velocity profile (UVP) and electrical resistance tomography (ERT) measurements [14,16,17]. The numerical results were also compared with numerical results using the species transport model.…”
Section: Introductionmentioning
confidence: 99%
“…The results of modeling the displacement of yoghurt by water were compared with experimental measurements of the velocity field and phase distribution [15]. The techniques used for the experimental measurements were ultrasonic velocity profile (UVP) and electrical resistance tomography (ERT) measurements [14,16,17]. The numerical results were also compared with numerical results using the species transport model.…”
Section: Introductionmentioning
confidence: 99%
“…The method for in-line rheometry employing the UVP technique combined with pressure difference (PD) measurements in a pipe section is based on this concept and is currently known as UVP-PD. The methodology used in this work has been developed and improved at SIK and is presented in detail in Wiklund et al (2002Wiklund et al ( , 2006Wiklund et al ( , 2007, Wiklund (2007), Wiklund and Stading (2008).…”
Section: Uvp-pd Methods and Instrumentationmentioning
confidence: 99%
“…Along this section, where MRI and UVP results are presented and discussed, the horizontal velocity profiles obtained using MRI, are indicated in the plots by MRI H , while the data obtained by each independent UVP probe are indicated as UVP 4 and UVP 9 , which refers to their respective hardware channel. Velocity data is used from each probe up to the channel centreline.…”
Section: Mri Vs Uvpmentioning
confidence: 99%
“…Ultrasound systems, based on echography and Doppler Effect, allowed the development of equipment capable of measuring almost instantaneous velocity profiles [8]. Initially, the Ultrasonic Velocity Profile (UVP) technique was limited to opaque fluids [9] and it was typically used to measure across pipe walls in small scale systems [10]. A UVP probe emits an ultrasound beam that travels along the axis and afterwards receives the echo from the same beam as reflected by small particles present in the fluid.…”
Section: Introductionmentioning
confidence: 99%