A Comparison of International Normalized Ratio Results by Point-of-Care Device and Clinical Laboratory Analyzers in a Vascular Surgery Department

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
1
1

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 32 publications
0
2
0
Order By: Relevance
“…Blood obtained from a finger puncture is placed onto strips containing a thrombin-specific electrogenic substrate, which releases the redox-active molecule when thrombin encounters the substrate, which is connected to a portable device that analyses the PT/INR values. Several studies utilised a Coagucheck XS coagulation analyser for the INR measurement of warfarin and LMWH [46][47][48][49]. Similarly, i-STAT (Abbott Diagnostics, Macquarie Park, Australia) and the Xprecia Stride coagulation analyser (Siemens Healthcare Diagnostics, Macquarie Park, Australia) also use a similar electrochemical platform [50][51][52][53].…”
Section: Electrochemical Sensors For Anticoagulants Using Thrombin-sp...mentioning
confidence: 99%
“…Blood obtained from a finger puncture is placed onto strips containing a thrombin-specific electrogenic substrate, which releases the redox-active molecule when thrombin encounters the substrate, which is connected to a portable device that analyses the PT/INR values. Several studies utilised a Coagucheck XS coagulation analyser for the INR measurement of warfarin and LMWH [46][47][48][49]. Similarly, i-STAT (Abbott Diagnostics, Macquarie Park, Australia) and the Xprecia Stride coagulation analyser (Siemens Healthcare Diagnostics, Macquarie Park, Australia) also use a similar electrochemical platform [50][51][52][53].…”
Section: Electrochemical Sensors For Anticoagulants Using Thrombin-sp...mentioning
confidence: 99%
“…Blood obtained from a finger puncture is placed onto strips containing thrombin-specific electrogenic substrate, which releases the redox active molecule when thrombin encounters the substrate, which is connected to a portable device that analyses PT/INR values. Several studies utilised a Coagucheck XS coagulation analyser for the INR measurement of warfarin and LMWH [46][47][48][49]. Similarly, i-STAT (Abbott Diagnostics) and Xprecia Stride coagulation analyser (Siemens Healthcare Diagnostics) also use a similar electrochemical platform [50][51][52][53].…”
Section: Electrochemical Sensors For Anticoagulants Using Thrombin-sp...mentioning
confidence: 99%