42nd International Conference on Environmental Systems 2012
DOI: 10.2514/6.2012-3534
|View full text |Cite
|
Sign up to set email alerts
|

A Comparison of Methods for Assessing Space Suit Joint Ranges of Motion

Abstract: Abstract:Through the Advanced Exploration Systems Program, NASA is attempting to use the vast collection of space suit mobility data from 50 years worth of space suit testing to build predictive analysis tools to aid in early architecture decisions for future missions and exploration programs. However, the design engineers must first understand if and how data generated by different methodologies can be compared directly and used in an essentially interchangeable manner. To address this question, the isolated … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2013
2013
2021
2021

Publication Types

Select...
4
4

Relationship

0
8

Authors

Journals

citations
Cited by 11 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…Due to how the data was acquired, we are thus far unable to quantify this variation. In order to do so, the first step would be to acquire the range of motion data for a statistically significant number of test subjects, also, if we take in account the considerations made by Aitchison in, 15 in order to have a valid estimate, the same system (or type of system) would be necessary. In this case we would require two variants of the BPMS system, one worn by the test subject and the second installed on the outer garment of the pressure suit.…”
Section: B Discussionmentioning
confidence: 99%
“…Due to how the data was acquired, we are thus far unable to quantify this variation. In order to do so, the first step would be to acquire the range of motion data for a statistically significant number of test subjects, also, if we take in account the considerations made by Aitchison in, 15 in order to have a valid estimate, the same system (or type of system) would be necessary. In this case we would require two variants of the BPMS system, one worn by the test subject and the second installed on the outer garment of the pressure suit.…”
Section: B Discussionmentioning
confidence: 99%
“…Table 1 lists some frequently adopted isolated joint motions. Please go to [4] for picture illustrations of these motions. Because functional motions are heavily dependently on the tasks to be carried out in space missions, they are not listed in such a table.…”
Section: Typical Motions In Mobility Measuremensmentioning
confidence: 98%
“…As far as the techniques used for measurement are concerned, there are three choices: manually measurement by anthropometrist; Photo Method used by JSC's space suit and human factors teams in 1999; 3D-MC Method used for 2009 Constellation Suit Requirements. For detailed explanations of the latter two techniques, please refer to [4]. Here we emphasize one phenomenon observed in several ROM measurements that fit was a key factor affecting suit mobility evaluations and joint mobility was sensitive to subject fit [5,6].…”
Section: Rom Measurementmentioning
confidence: 99%
“…Around joint mobility, many kinds of spacesuit joint had been developed, including flat-pattern joint, bellow-type joint, and rotation-bearing joint. Now, there are many research achievements in motion analysis and test [13,14], computational methods [15,16], human factors [17,18], and joint development [19,20]. As far as joint design is concerned, there is relatively less research on the improvement of hard joint design for many years.…”
Section: Introductionmentioning
confidence: 99%