A Comparison of the Edge Testing of Indirect Composite Layered Zirconia Crowns and Monolithic Zirconia Crowns Without Aging: An In Vitro Study

Maaz Vohra,
Nabeel Ahmed,
Varun Keskar
et al.

Abstract: Introduction The main reason veneered zirconia restorations fail is due to porcelain veneer chipping. This chipping usually starts from wear marks on the chewing surface. As a result, small cracks under the contact area can grow into larger ones across the veneer layer. The veneer ceramic layer is more vulnerable to fractures because it has lower toughness and slightly lower stiffness compared to the base framework material. Thus, even when there's significant chipping, the main framework material u… Show more