2010
DOI: 10.1021/la903387n
|View full text |Cite
|
Sign up to set email alerts
|

A Comparison of the Higher Order Harmonic Components Derived from Large-Amplitude Fourier Transformed ac Voltammetry of Myoglobin and Heme in DDAB Films at a Pyrolytic Graphite Electrode

Abstract: A debate as to whether heme remains bound or is released in myoglobin molecules incorporated into a didodecyldimethylammonium bromide (DDAB) film adhered to a pyrolytic graphite electrode has prompted a comparison of their electrochemistry by the highly sensitive large-amplitude Fourier transformed ac voltammetric method. The accessibility of third, fourth, and higher harmonic components that are devoid of background current and the enhanced resolution relative to that available in dc voltammetry have allowed … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
23
0

Year Published

2011
2011
2017
2017

Publication Types

Select...
7
2

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(25 citation statements)
references
References 60 publications
2
23
0
Order By: Relevance
“…Bond and coworkers [646][647][648][649][650][651][652][653][654][655][656][657] have proposed use of the ac voltammetry with large ac signal superimposed on the linear sweep. The applied potential and measured current are presented in Fig. 15.4. Then, to analyze the obtained current, a Fourier transform is applied and the responses at the fundamental, ω, and harmonic, 2ω, 3ω, 4ω,.…”
Section: Exercisesmentioning
confidence: 99%
“…Bond and coworkers [646][647][648][649][650][651][652][653][654][655][656][657] have proposed use of the ac voltammetry with large ac signal superimposed on the linear sweep. The applied potential and measured current are presented in Fig. 15.4. Then, to analyze the obtained current, a Fourier transform is applied and the responses at the fundamental, ω, and harmonic, 2ω, 3ω, 4ω,.…”
Section: Exercisesmentioning
confidence: 99%
“…54 These conclusions were confirmed recently by Lee and Bond using higher order harmonics of large-amplitude Fourier transformed AC voltammetry. 56 Also, cyt P450 cam in DDAB films was active for epoxidation of styrene to styrene oxide from electrolysis using P450 cam -DDAB films on carbon cloth electrodes. 23 Thus, structural integrity and catalytic activity of cyt P450s in surfactant films require careful control of conditions such as pH and Br - content used to make and analyze the films.…”
Section: Overview Of Thin Film Voltammetry and Biocatalysis With mentioning
confidence: 99%
“…Two pairs of weak quasi-reversible redox peaks (curve c) with formal potentials ((E red p + E ox p )/2) of −0.171 and −1.058 V were obtained on DDAB/Hb/GCE in 0.10 M pH 7.0 PBS. Obviously, the two pairs of redox peaks are attributed to the redox of HbFe(III)/HbFe(II) and HbFe(II)/HbFe(I) couples, respectively [20], suggesting the facilitation of DET between entrapped Hb and electrode. Interestingly, the current response of the two redox couples increased greatly when DDAB/Hb/GCE was in 6.0 M urea (curve d, 0.1 M pH 7.0 PBS).…”
Section: Electrochemical Behavior Of Ddab/hb/gcementioning
confidence: 98%