A comparison of various procedures in photon activation analysis with the same irradiation setup

Abstract: a b s t r a c tA sample of known elemental concentrations was activated in the bremsstrahlung photon beam which was created by a pulsed electron LINAC. Several procedures of photon activation analysis, including those applied with/without reference material and with/without photon flux monitor, were conducted to make a comparison of their precision and accuracy in practice. Experimental results have indicated that: (1) relative procedures usually produce better outcome despite that the absolute measurement is … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2015
2015
2018
2018

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 10 publications
(7 citation statements)
references
References 16 publications
0
7
0
Order By: Relevance
“…6. G4 underestimates the photoneutron yields by a factor of $500 because the model cannot reproduce the experimental 9 Be(c, n) 8 Be reaction cross-section as was shown in Fig. 2(a).…”
Section: Data-based Photonuclear Modelmentioning
confidence: 95%
See 3 more Smart Citations
“…6. G4 underestimates the photoneutron yields by a factor of $500 because the model cannot reproduce the experimental 9 Be(c, n) 8 Be reaction cross-section as was shown in Fig. 2(a).…”
Section: Data-based Photonuclear Modelmentioning
confidence: 95%
“…Also the model does not reproduce the low-energy peaks. Such discrepancies may come from the underestimation of the neutron production for the 9 Be(c, n) 8 Be reaction. The neutrons from the 9 Be(c, 2n) 7 Be reaction, which has a threshold energy E th of $20.588 MeV, do not contribute to the neutron production in the E c < $16 MeV region.…”
Section: Benchmark Test Of Geant4 Simulation For Photonuclear Interacmentioning
confidence: 99%
See 2 more Smart Citations
“…Traditionally, to calculate the activity from pulse irradiation, scientists usually expand the usage of continuous irradiation Equations (1) and (2) into applications of pulse irradiation without too much consideration of details in pulses. Instead of peak flux in the pulse width, they use average particle flux during the whole irradiation period to calculate the final radioactivity [2][3][4][5]. This practice does make sense at the first thought: the repetition rate of pulses is usually relatively high, the irradiation can be regarded as continuous from the point of whole irradiation period, and the half-life of the product nuclides of interest are usually long even comparable to the whole irradiation time.…”
Section: Introductionmentioning
confidence: 99%