2020
DOI: 10.11591/ijeecs.v19.i1.pp301-308
|View full text |Cite
|
Sign up to set email alerts
|

A comprehensive review for optimal placement of phasor measurement unit for network observability

Abstract: Real time synchronized phasor measurement in power network is obtained by the improvement in monitoring, control and, protection of the power system. In recent time, the installation ratio of Phasor Measurement Units (PMUs) is constantly increasing for the real time measurement throughout worldwide. The increment in the number of PMU installation is to only focus on the improvement of system state estimation (SE) performance. However, the expensive nature of the metering device requires huge amount of installa… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
4
2

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 19 publications
0
3
0
Order By: Relevance
“…Misclassification of metaheuristic techniques presented is correctly presented in our paper. Baba et al [21] reviewed a few published articles available in the literature about OPP for network observability. Johnson et al [22] reviewed different properties of OPP formulation and shortcomings of the techniques in OPP.…”
Section: Existing Surveys In Oppmentioning
confidence: 99%
“…Misclassification of metaheuristic techniques presented is correctly presented in our paper. Baba et al [21] reviewed a few published articles available in the literature about OPP for network observability. Johnson et al [22] reviewed different properties of OPP formulation and shortcomings of the techniques in OPP.…”
Section: Existing Surveys In Oppmentioning
confidence: 99%
“…Although measurements are scanned through out the system, the system's state is presumed to be static.Whereas power systems are operated completely dynamic in nature. High price tags of PMUs forced the researchers to investigate the optimal locations for the complete observability of the electric network [20]- [27].…”
Section: Synchrophasor Measurements and Pmu Standardsmentioning
confidence: 99%
“…This measurement is somehow bearable to monitor the power system in a stable condition; however, during the uncertainty and disturbance in the electrical network, this measurement level is not good enough to monitor the varying effects in the system. The lack of monitoring, controlling, and protecting performance in the previous devices was noticed, therefore a novel device was introduced with Global Positioning Systems (GPS) and digital signal processing (DSP) in the late 1980s in the research laboratory of the University of Virginia [3]. In the latest survey according to North America Synchrophasor Initiative (NASPI), there are nearly 2000 PMU devices installed in the North American transmission and distribution network [4].…”
Section: Introductionmentioning
confidence: 99%
“…The real-time synchronized measurement is obtained by the improvement in monitoring, protection, and control of the power system [3]. Similarly, PMU provides the real-time synchronized measurement, synchronized frequency, rate of change of frequency of voltage, current phasor quantities, and their magnitude with a high precision rate of ±1 • or ±1% [2][3][4][5][6][7][8] with the support of GPS [14,15]. The measurement level of PMUs is very high -nearly 60 samples of measurement per cycle as compared to the traditional devices [16].…”
Section: Introductionmentioning
confidence: 99%