2019
DOI: 10.1007/s40565-019-00570-6
|View full text |Cite
|
Sign up to set email alerts
|

A contingency-aware method for N-2 security-constrained transmission expansion planning

Abstract: In this paper, a novel contingency-aware method for N-2 security-constrained transmission expansion planning is proposed. To ensure that the transmission construction plan satisfies the N-2 security criterion, the proposed method takes advantage of the adjustable robust optimization (ARO) framework and upgrades it. We construct a discrete uncertainty set in which component failures are treated as uncertain events that are handled as binary variables. In addition to the failure of existing lines and generators,… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 13 publications
(3 citation statements)
references
References 29 publications
0
3
0
Order By: Relevance
“…Therefore, in response to the aforementioned issues, this paper draws upon the theoretical foundations of power grid planning (Majidi-Qadikolai and Baldick, 2016;Garcí a-Bertrand and Mí nguez, 2017;LIU et al, 2019) and incorporates engineering practicalities. Considering the costeffectiveness and safety implications, we propose the development of a comprehensive planning model for the maintenance of 220 kV substations on the basis of economic and reliability considerations.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Therefore, in response to the aforementioned issues, this paper draws upon the theoretical foundations of power grid planning (Majidi-Qadikolai and Baldick, 2016;Garcí a-Bertrand and Mí nguez, 2017;LIU et al, 2019) and incorporates engineering practicalities. Considering the costeffectiveness and safety implications, we propose the development of a comprehensive planning model for the maintenance of 220 kV substations on the basis of economic and reliability considerations.…”
Section: Discussionmentioning
confidence: 99%
“…Reference proposes combining electric vehicles and HVAC systems to increase flexibility and participate in ancillary services. Reference (Liu et al, 2019) utilizes a house energy management system to participate in peak shaving services for the power grid. Reference (Yang et al, 2015) proposed a specific implementation method for public buildings to participate in peak shaving services, dividing building management into building-level, terminal-level, communication-level, and primary station levels and managing it from bottom to top.…”
Section: Ieeementioning
confidence: 99%
“…Therefore, in response to the aforementioned issues, this paper draws upon the theoretical foundations of power grid planning (Majidi-Qadikolai and Baldick, 2016;Garcí a-Bertrand and Mí nguez, 2017;ZHANG et al, 2017;LIU et al, 2019) and incorporates engineering practicalities. Considering the costeffectiveness and safety implications, we propose the development of a comprehensive planning model for the maintenance of 220 kV substations on the basis of economic and reliability considerations.…”
Section: Introductionmentioning
confidence: 99%