A controller design method for 3 phase 4 wire grid connected VSI with LCL filter

Abstract: Closed loop control of a grid connected VSI requires line current control and dc bus voltage control. The closed loop system comprising PR current controller and grid connected VSI with LCL filter is a higher order system. Closed loop control gain expressions are therefore difficult to obtain directly for such systems. In this work a simplified approach has been adopted to find current and voltage controller gain expressions for a 3 phase 4 wire grid connected VSI with LCL filter. The closed loop system consid… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2016
2016
2018
2018

Publication Types

Select...
3
2

Relationship

3
2

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 22 publications
0
4
0
Order By: Relevance
“…The proposed control architecture is shown in Fig. 3, where the PLEC is operated in current controlled mode using an inner current loop consisting of a proportional resonant controller (G pri (s)) operating in stationary reference frame [10] and an outer reference generator block providing the required current reference derived from the sensed grid voltage. The bode plots of loop transfer function (G pri (s).G i (s)) and closed loop transfer function of current loop are shown in Fig.…”
Section: A Impedance Emulation During Grid Connected Mode Of Operatimentioning
confidence: 99%
See 1 more Smart Citation
“…The proposed control architecture is shown in Fig. 3, where the PLEC is operated in current controlled mode using an inner current loop consisting of a proportional resonant controller (G pri (s)) operating in stationary reference frame [10] and an outer reference generator block providing the required current reference derived from the sensed grid voltage. The bode plots of loop transfer function (G pri (s).G i (s)) and closed loop transfer function of current loop are shown in Fig.…”
Section: A Impedance Emulation During Grid Connected Mode Of Operatimentioning
confidence: 99%
“…Calculation of K iri is done by assuming that a band of ± ω o rad/sec around ω o rad/sec in magnitude plot of G pri (s) always has a gain of K i [10].…”
Section: A Impedance Emulation During Grid Connected Mode Of Operatimentioning
confidence: 99%
“…A fundamental frequency PR controller is implemented in the above-described method for a grid-connected application. Tuning of the controller gains are based on [33]. Grid voltage and current waveform for SS operation of the VSI with LCL filter as an static compensator (STATCOM) are shown in Fig.…”
Section: Experimental Validationmentioning
confidence: 99%
“…The inner loop controls the current by a proportional resonant controller. The outer loop controls the dc bus voltage using a PI controller [16].…”
Section: Controller For Afecmentioning