2004
DOI: 10.1109/tmtt.2004.837155
|View full text |Cite
|
Sign up to set email alerts
|

A Coplanar-Waveguide System for Cells Exposure During Electrophysiological Recordings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
14
0

Year Published

2007
2007
2019
2019

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 27 publications
(14 citation statements)
references
References 11 publications
0
14
0
Order By: Relevance
“…The exposure system, especially designed for electrophysiological patch-clamp recording, has been described elsewhere [Liberti et al, 2004]. Briefly, it is an open propagating structure consisting of a Co-Planar Wave-guide (CPW) (22.0 cm  10.2 cm  0.4 cm).…”
Section: Cell Exposure To Rfmentioning
confidence: 99%
See 1 more Smart Citation
“…The exposure system, especially designed for electrophysiological patch-clamp recording, has been described elsewhere [Liberti et al, 2004]. Briefly, it is an open propagating structure consisting of a Co-Planar Wave-guide (CPW) (22.0 cm  10.2 cm  0.4 cm).…”
Section: Cell Exposure To Rfmentioning
confidence: 99%
“…In this way it is possible to minimize the interference of the field with the electrode (i.e., with the current being measured). Moreover, measurements conducted in scattering parameters showed a low interaction of the system with the laboratory equipment, for example, the microscopic objective [Liberti et al, 2004]. Actually, even though the microscope objective may induce a local perturbation of the field below the substrate, it minimally influences the overall behavior of the exposure system.…”
Section: Cell Exposure To Rfmentioning
confidence: 99%
“…Moreover, it should provide an error estimation in order to minimize uncertainty and guarantee the correctness of the solution for each model. Several numerical methods have been employed for Petri dish simulations exposed to EM fields in different configurations, e.g., [3,20,21,16,1,22,23]. Approaches based on differential formulations are mainly used because of their flexibility to deal with complex geometrical and material configurations.…”
Section: Introductionmentioning
confidence: 99%
“…For real-time investigation, specific exposure systems have also been designed incorporating multiple electrode arrays (MEA) [7][8][9] and coplanar waveguides [10,11]. A few studies include monitoring of the sample using microscopic imaging.…”
Section: Introductionmentioning
confidence: 99%