2013
DOI: 10.1039/c3ay40727f
|View full text |Cite
|
Sign up to set email alerts
|

A coprecipitation procedure for the determination of some metals in food and environmental samples by flame atomic absorption spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
9
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(9 citation statements)
references
References 23 publications
0
9
0
Order By: Relevance
“…The LODs are listed in Table 5. As can be seen, for copper analysis based on the atomic spectroscopic method using SPE, the LOD of this work was at least one order of magnitude lower than that using the methods of Yalcınkaya et al, 31 Ghaedi et al 32 and Dai et al, 33 2-4 times lower than that by the methods of Özdemir et al, 34 Zhu et al, 35 Nomngongo et al, 36 and Rao et al, 37 and was comparable with other AAS methods, 38,39 showing the high sensitivity of the proposed method for copper ions. Also, the recoveries of copper ions from various real samples are satisfactory.…”
Section: Analysis Of Real Samplesmentioning
confidence: 56%
See 1 more Smart Citation
“…The LODs are listed in Table 5. As can be seen, for copper analysis based on the atomic spectroscopic method using SPE, the LOD of this work was at least one order of magnitude lower than that using the methods of Yalcınkaya et al, 31 Ghaedi et al 32 and Dai et al, 33 2-4 times lower than that by the methods of Özdemir et al, 34 Zhu et al, 35 Nomngongo et al, 36 and Rao et al, 37 and was comparable with other AAS methods, 38,39 showing the high sensitivity of the proposed method for copper ions. Also, the recoveries of copper ions from various real samples are satisfactory.…”
Section: Analysis Of Real Samplesmentioning
confidence: 56%
“…The recoveries ranged between 90 and 111% for Cu 2+ in the spiked environmental water samples and food samples, which indicated the good selectivity of the proposed method for the determination of trace Cu 2+ . The present method was compared with analytical methods previously published in the literature [31][32][33][34][35][36][37][38][39] for the analysis of copper ions in terms of LOD and recovery. The LODs are listed in Table 5.…”
Section: Analysis Of Real Samplesmentioning
confidence: 99%
“…Presently, a diverse array of analytical techniques exists for ultrasensitive detection (down to the fM level) of trace analytes. These encompass a variety of approaches, including spectroscopy-based methods, such as atomic absorption spectrometry (ppb to ppm range), inductively coupled plasma atomic emission spectrometry (ppb to ppm range), and inductively coupled plasma mass spectrometry (ppt to ppb range). Additionally, electrochemical techniques, such as potentiometry employing ion-sensitive electrodes and stripping voltammetry (nM to pM range), are widely employed . Furthermore, X-ray-based methods like X-ray fluorescence (ppm to ppb range) are also valuable tools in this regard …”
Section: Introductionmentioning
confidence: 99%
“…In view of this harmful effect, it is very important to detect heavy metals in farm products. Conventional elemental analysis techniques, such as atomic absorption spectrometry (AAS) [1] , inductively coupled plasma-optical emission spectroscopy (ICP-OES) [2] , and inductively coupled plasma-mass spectroscopy (ICP-MS) [3] , have higher sensitivity and accuracy and better detect limit. But the above methods need complex preprocessing of samples and consume plenty of chemical reagents.…”
Section: Introductionmentioning
confidence: 99%