A cost-benefit analysis of implementing a 54 MW solar PV plant in a South African platinum mining company: A case study

Abstract: A reliable and secure supply of energy is a prerequisite for adequate output and economic growth – especially in a platinum mining company. With exponential tariff increases, inadequate power supply leading to power cuts, and a carbon tax introduction, this study compared the costs with benefits by implementing a 54 MW solar photovoltaic (PV) plant. Two scenarios were compared over the same 20-year period in a case study of a South African platinum mining company operating in the platinum belt of Rustenburg. T… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 11 publications
(9 reference statements)
0
4
0
Order By: Relevance
“…For the optimistic case scenario, a 25% wind and 75% solar-based energy generation capacity system results in a slightly lower LCOE (∼0.14 USD/kWh). Notably, this indicates that the reduction in the costs of the PV system from 961 USD/kW in the conservative scenario to 618 USD/kWh in the optimistic has nearly no impact in the final LCOE. For both cases, a battolyzer + AE-HB design capacity of 20–30% of the theoretically assumed realistic maximum is found to be the optimum between battolyzer + AE-HB CapEx and wind/solar PV-based energy generation CapEx.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…For the optimistic case scenario, a 25% wind and 75% solar-based energy generation capacity system results in a slightly lower LCOE (∼0.14 USD/kWh). Notably, this indicates that the reduction in the costs of the PV system from 961 USD/kW in the conservative scenario to 618 USD/kWh in the optimistic has nearly no impact in the final LCOE. For both cases, a battolyzer + AE-HB design capacity of 20–30% of the theoretically assumed realistic maximum is found to be the optimum between battolyzer + AE-HB CapEx and wind/solar PV-based energy generation CapEx.…”
Section: Discussionmentioning
confidence: 99%
“…For wind turbines, an installed cost of 1877 USD/kW has been estimated . For solar energy, installed costs of 961 and 618 USD/kW for base case and good case scenarios have been estimated, respectively. , The effect of solar CapEx on LCOE has been illustrated in the Supporting Information. Further readings into the utilized cost estimation method including bare erected cost (BEC) estimation methods can be found in the Supporting Information of the previous work from our group …”
Section: Methodsmentioning
confidence: 99%
“…It can be obtained from the official website of the Bureau of Energy in Taiwan. Carbon emission factors vary slightly for each country, so the calculation uses the local factor [40,41]. Table 2 shows the carbon emission factor from 2015 to 2021, which is obtained from the Bureau of Energy.…”
Section: Carbon Reduction Analysismentioning
confidence: 99%
“…A cost-benefit analysis informs investment decision-making for renewable energy and environmental systems and has been used for solar photovoltaic systems [40], renewable energy systems [41], tidal energy production [42], river restoration [43], and wastewater reuse [44]. The decision indicators for a cost-benefit analysis include net present value (NPV), benefit-cost ratio (BCR), internal rate of return (IRR), and payback period (PR).…”
Section: Cost and Benefit Analysismentioning
confidence: 99%