2008
DOI: 10.1002/micr.20512
|View full text |Cite
|
Sign up to set email alerts
|

A critical evaluation of the concomitant use of the implantable Doppler probe and the Vacuum Assisted Closure system in free tissue transfer

Abstract: Introduction of the Vacuum-Assisted Closure (V.A.C.) system has revolutionized the approach to a multitude of clinical settings. Yet, its use precludes adequate clinical monitoring of skin-grafted free flaps, thus, making a reliable monitoring system essential if broad clinical application is aspired. In a clinical study, the usefulness of the combination of the V.A.C. and implantable Doppler probe was critically evaluated in patients with microsurgical lower extremity reconstruction. We retrospectively analyz… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
20
0

Year Published

2010
2010
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(21 citation statements)
references
References 21 publications
1
20
0
Order By: Relevance
“…1). [21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36] There was only one prospective randomized trial 27 ; the other 15 studies were all retrospective observational studies with low-level evidence according to the Oxford classification of evidence-based medicine (►Table 1). The first article on this topic was published in 2004, 31 and the remaining articles were published within the past 10 years (►Table 1).…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…1). [21][22][23][24][25][26][27][28][29][30][31][32][33][34][35][36] There was only one prospective randomized trial 27 ; the other 15 studies were all retrospective observational studies with low-level evidence according to the Oxford classification of evidence-based medicine (►Table 1). The first article on this topic was published in 2004, 31 and the remaining articles were published within the past 10 years (►Table 1).…”
Section: Resultsmentioning
confidence: 99%
“…According to the reconstruction maneuver, there were 18 (13.1%) local random flaps, 21,22 21 (15.3%) pedicle flaps, 29,[31][32][33]36 and 98 (71.5%) free flaps. [23][24][25][26][27][28]30,[32][33][34][35] However, the articles were divided into groups based on the purpose of NPWT application. The details are presented in ►Tables 2 to 5.…”
Section: Resultsmentioning
confidence: 99%
“…[23][24][25][26][27] Difficulty in the interpretation of back and forth motion of blood in the internal mammary vein, however, may occur. This can be tested by listening if the signal stops after clamping the vein.…”
Section: Implantable Doppler Systemmentioning
confidence: 94%
“…The facial artery and vein were used as recipient vessels ( Figure 1A), and patency of the anastomosis was monitored after microanastomosis by an implantable Doppler probe attached to the draining vein. 7,8 Doppler signal was normal in all patients, and the implantable Doppler probe was removed on the seventh postoperative day without complications. Six months after this second complicationfree procedure, no muscle excursion was observed, or the resulting muscle contraction was too weak to generate a symmetrical smile.…”
Section: Observationsmentioning
confidence: 98%