2003
DOI: 10.1109/tpwrd.2003.817790
|View full text |Cite
|
Sign up to set email alerts
|

A detailed model for a thyristor-based static transfer switch

Abstract: Industrial customers often suffer from supply voltage interruptions and sags due to the increase in the utilization of sensitive equipment in the process automation and control. An effective way to improve power quality and reliability of sensitive customers is to use a static transfer switch. This device enables a very fast change in the supply of the customer to an alternate feeder providing adequate power conditioning for several power quality problems, such as voltage sags, swells, and interruptions. In th… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0
2

Year Published

2007
2007
2021
2021

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 26 publications
(10 citation statements)
references
References 8 publications
0
8
0
2
Order By: Relevance
“…[4] Also, it has an advantage that possible wrong may not exist in power supply of load even if a critical situation including control function fault of UPS's interior happens. [5] 2. UPS's problem in industrial a) Accident of the industrial field Actual condition analysis of STS operation in an industrial field.…”
Section: Introductionmentioning
confidence: 99%
“…[4] Also, it has an advantage that possible wrong may not exist in power supply of load even if a critical situation including control function fault of UPS's interior happens. [5] 2. UPS's problem in industrial a) Accident of the industrial field Actual condition analysis of STS operation in an industrial field.…”
Section: Introductionmentioning
confidence: 99%
“…Several researchers addressed the problem of the cross current [11][12][13][14][15][16][17]. According to [14,15], a relationship exists between the magnitude of the cross current and the phase difference between the two feeders.…”
Section: Cross Current Phenomenonmentioning
confidence: 99%
“…Operation of a sensitive load can be disturbed by the common voltage sags, swells and interruptions. Recent studies [7][8][9][10][11][12][13][14][15][16][17][18][19] identify solid-state transfer switch (STS) as a possible cost effective solution to power quality problems. STS, see Fig.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…In the distribution system of the utility (rather than customer) side, there are several approaches to improve the voltage dip phenomena: Static Transfer Switch (STS) [1][2][3][4], Transient Voltage Restorer (TVR), and Static Tap Changer (STC) [5]. The STS enables a sensitive load to transfer its power consumption from one source to another during 0.25 cycles.…”
Section: Introductionmentioning