2013
DOI: 10.1109/tii.2012.2223223
|View full text |Cite
|
Sign up to set email alerts
|

A DSP-Based Implementation of the $p{\hbox{–}}q$ Theory in Active Power Filtering Under Nonideal Voltage Conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
72
0

Year Published

2013
2013
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 113 publications
(72 citation statements)
references
References 37 publications
0
72
0
Order By: Relevance
“…Also, the instantaneous compensation current i c calculated by using the instantaneous load current i L described as (2), and i c is formulated by (3). As shown in Fig.…”
Section: Graphical Representation Of the Instantaneous Compensation Pmentioning
confidence: 99%
See 1 more Smart Citation
“…Also, the instantaneous compensation current i c calculated by using the instantaneous load current i L described as (2), and i c is formulated by (3). As shown in Fig.…”
Section: Graphical Representation Of the Instantaneous Compensation Pmentioning
confidence: 99%
“…Active power filters(APFs) [1][2][3][4][5][6][7][8][9][10][11] have been accepting as an efficient device for compensating the harmonics and reactive power of nonlinear loads such as thyristor controlled rectifiers or variable speed drives. In order to compensate the harmonics and reactive power using APFs, APFs should be operated to the instantaneous rectification mode and the instantaneous inversion mode during the compensation operation.…”
Section: Introductionmentioning
confidence: 99%
“…Under balanced and sinusoidal source voltage conditions, various research works on this particular algorithm have been reported in the literature such as synchronous reference frame (SRF) [20][21][22], instantaneous power (pq) theory [2,[23][24][25], dq-axis with Fourier (dqF) [26], fast Fourier transform (FFT) [27], synchronous detection (SD) [28,29] and artificial neural network (ANN) [30,31]. Nevertheless, among the available algorithms, pq theory algorithm provides the best advantages which include simple design, increased speed and fewer calculations, and thus makes it more likely to be implemented practically.…”
Section: Introductionmentioning
confidence: 99%
“…This paper presents the implementation of APF in order to verify the performance comparison of the PI and P+RES controllers. From the literature reviews, the control strategy for APF can be implemented by analog circuits (one cycle control [19], PI control [20], quasi steady state control [21]) and digital techniques (adaptive linear element (Adaline) control [22], PI control [23], hysteresis control [24], fuzzy logic control [25], predictive control [26], one cycle control [27]). The advantages of analog circuits are fast computational time (no sampling time) and low cost.…”
Section: Introductionmentioning
confidence: 99%