2022
DOI: 10.3390/electronics11050740
|View full text |Cite
|
Sign up to set email alerts
|

A Dual-Armed Robotic Puncture System: Design, Implementation and Preliminary Tests

Abstract: Traditional renal puncture surgery requires manual operation, which has a poor puncture effect, low surgical success rate, and high incidence of postoperative complications. Robot-assisted puncture surgery can effectively improve the accuracy of punctures, improve the success rate of surgery, and reduce the occurrence of postoperative complications. This paper provides a dual-armed robotic puncture scheme to assist surgeons. The system is divided into an ultrasound scanning arm and a puncture arm. Both robotic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 25 publications
0
2
0
Order By: Relevance
“…The puncture actuator controlling channel is in charge of automatically inserting a needle and compensating for the motion of the internal organs. Gao et al [ 108 ] used a master–slave control strategy based on the differential motion increment of the Jacobi inverse matrix with error compensation in the use of ultrasound-guided dual-arm robotic puncture, and this master–slave control algorithm reduces the computation time required for puncture, meets the demand for image guidance, and improves the success rate of the puncture procedure. Li et al [ 109 ] proposed an improved linear rotation automatic calibration algorithm to reduce errors caused by manual calibration and system noise, aiming at the problem that the calibration accuracy of surgical gaps affects the accuracy of surgical system.…”
Section: Optimization Methods Of Medical Image Navigation Technology ...mentioning
confidence: 99%
“…The puncture actuator controlling channel is in charge of automatically inserting a needle and compensating for the motion of the internal organs. Gao et al [ 108 ] used a master–slave control strategy based on the differential motion increment of the Jacobi inverse matrix with error compensation in the use of ultrasound-guided dual-arm robotic puncture, and this master–slave control algorithm reduces the computation time required for puncture, meets the demand for image guidance, and improves the success rate of the puncture procedure. Li et al [ 109 ] proposed an improved linear rotation automatic calibration algorithm to reduce errors caused by manual calibration and system noise, aiming at the problem that the calibration accuracy of surgical gaps affects the accuracy of surgical system.…”
Section: Optimization Methods Of Medical Image Navigation Technology ...mentioning
confidence: 99%
“…Research by [8] with the title Design of 5 Degrees of Freedom Robot Arm with Kinematics Approach. Research by [9] with the title Design and development of a robotic arm. Then Research by [10] with the title Design and Construction of a Robotic Arm For Industrial Automation.…”
Section: Introductionmentioning
confidence: 99%
“…Shi et al [4] developed a control strategy based on torque estimation and made it responsible for the intention understanding and motion servo of this customized system. Gao et al [5] provided a dual-armed robotic puncture scheme to assist surgeons. The system was divided into an ultrasound scanning arm and a puncture arm.…”
mentioning