1996
DOI: 10.1088/0957-0233/7/3/010
|View full text |Cite
|
Sign up to set email alerts
|

A dual sensor flow imaging tomographic system

Abstract: A dual sensor tomograph for three-component flow imaging has been built at the University of Bergen in cooperation with Christian Michelsen Research AS and Norsk Hydro AS. It utilizes an eight-electrode electrical capacitance tomograph and a γ-ray tomograph with five radiation sources and 85 compact detectors. Embedded transputers using memory-mapped I/O ensure high-speed data acquisition into an Alpha AXP-based on-line processing unit. The first results demonstrate that three-component flow regime identificat… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
60
0
1

Year Published

1998
1998
2018
2018

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 120 publications
(61 citation statements)
references
References 14 publications
0
60
0
1
Order By: Relevance
“…A hard-field system, such as optical tomography, is equally sensitive to the parameter it measures in all positions throughout the measurement volume [4]. Soft-field Table 1 The advantages and limitations of tomography modalities in solid/gas flow measurement…”
Section: Overview Of System Designmentioning
confidence: 99%
See 3 more Smart Citations
“…A hard-field system, such as optical tomography, is equally sensitive to the parameter it measures in all positions throughout the measurement volume [4]. Soft-field Table 1 The advantages and limitations of tomography modalities in solid/gas flow measurement…”
Section: Overview Of System Designmentioning
confidence: 99%
“…Limited measurement in high distribution flows above 35% [2] Gamma ray Spatial resolution 1% [3,4] Require relatively long time for energy integration, mechanical movement to obtain of the whole region [4,6], radiation dose to the surrounding [3,4], heavy shielding [4] Dual mode; electrical capacitance and gamma…”
Section: Sensing Principle Advantages Limitationsmentioning
confidence: 99%
See 2 more Smart Citations
“…water in bubble column) [2]. Indeed, there are several other tomography techniques available but optical tomography is considered safest technique since this sensors is equally sensitive to parameter measured in all position throughout the measurement volume and its sensitivity is independent on the distribution inside and outside measurement region [3].…”
Section: 10 Introductionmentioning
confidence: 99%