A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
32
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 21 publications
(33 citation statements)
references
References 12 publications
1
32
0
Order By: Relevance
“…A variety of detectors and phantoms may be considered for daily QA measurements (Section VI). Which detector or phantom to use depends on the type of measurement to be made . For daily QA checks, phantoms that are easy to set up and reproducible are desirable; for example, a near‐water‐equivalent plastic.…”
Section: Daily Quality Assurance Proceduresmentioning
confidence: 99%
See 1 more Smart Citation
“…A variety of detectors and phantoms may be considered for daily QA measurements (Section VI). Which detector or phantom to use depends on the type of measurement to be made . For daily QA checks, phantoms that are easy to set up and reproducible are desirable; for example, a near‐water‐equivalent plastic.…”
Section: Daily Quality Assurance Proceduresmentioning
confidence: 99%
“…Which detector or phantom to use depends on the type of measurement to be made. 91,92 For daily QA checks, phantoms that are easy to set up and reproducible are desirable; for example, a near-water-equivalent plastic. Regardless of the phantom material chosen, the relative linear stopping power (RLSP), the energy dependence of the RLSP, and effects of nuclear interactions should be known.…”
Section: A Beam Dosimetry Parametersmentioning
confidence: 99%
“…Several authors have published on proton daily QA using either commercial or in‐house developed devices . Arjomandy et al .…”
Section: Introductionmentioning
confidence: 99%
“…included beam characteristics (spot width, size, and position), range, and dose output for the dosimetric component of daily QA. Another PBS daily QA paper was published in 2017 by Bizzocchi et al . and investigated the use of MatriXX‐PT (IBA Dosimetry, Schwarzenbruck, Germany) with an in‐house phantom to evaluate range, spot size and position, and dose output.…”
Section: Introductionmentioning
confidence: 99%
“…However, this method is limited to verifying only one or two energies. Dual wedges were used for proton range daily QA with MatriXX‐PT (IBA Dosimetry, Schwarzenbruck, Germany), but its accuracy was limited by the 7.6 mm coarse resolution of the MatriXX‐PT.…”
Section: Introductionmentioning
confidence: 99%