2011
DOI: 10.1016/j.jelechem.2011.04.011
|View full text |Cite
|
Sign up to set email alerts
|

A fast and simple electrochemical impedance spectroscopy measurement technique and its application in portable, low-cost instrument for impedimetric biosensing

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

1
20
0

Year Published

2014
2014
2019
2019

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 20 publications
(21 citation statements)
references
References 20 publications
1
20
0
Order By: Relevance
“…These methods using Fourier transformation are called FFT impedance or FT-EIS. It was reported that white noise [11,12], pseudo-random noise (pseudo-white noise) [12][13][14][15][16][17], pseudo-random signals [18], multi-sine waves (superimposed sine waves) [19,20], step signals [10,12,[21][22][23][24][25], and square pulses [26,27] can be applied to FFT impedance. An on-line FFT impedance measurement system using pseudo-white noise as the input signal was developed by one of our authors [14,15], and its application to in situ EIS was reported [15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…These methods using Fourier transformation are called FFT impedance or FT-EIS. It was reported that white noise [11,12], pseudo-random noise (pseudo-white noise) [12][13][14][15][16][17], pseudo-random signals [18], multi-sine waves (superimposed sine waves) [19,20], step signals [10,12,[21][22][23][24][25], and square pulses [26,27] can be applied to FFT impedance. An on-line FFT impedance measurement system using pseudo-white noise as the input signal was developed by one of our authors [14,15], and its application to in situ EIS was reported [15][16][17].…”
Section: Introductionmentioning
confidence: 99%
“…Since the full impedance spectrum is a time-consuming technique, Huang et al [50] employed a potential stepbased time domain impedance measurement. All the operational amplifiers in the potentiostat have a bandwidth greater than 1 MHz.…”
Section: Journal Of Sensorsmentioning
confidence: 99%
“…In all cases, the potentiometric response is determined by ion conduction processes and ion exchange reactions at Figure 17: Impedance spectra obtained by the STP method with varied sampling rates and the FRA method (red line). Reprinted from [50]. From an analysis of the works addressing the design of potentiometric potentiostats in the recent literature, the main concerns are the input impedance and input bias current.…”
Section: Potentiometric Protein Detectionmentioning
confidence: 99%
See 1 more Smart Citation
“…A small low-cost impedance measurement board using a microprocessor and several operational amplifiers for portable biosensing applications is presented in [7], where a voltage step is applied to the device under test (DUT) and the current is measured and sampled using analog-to-digital conversion (ADC). A DSP-based embedded frequency response analyzer for fuel cell monitoring and characterization is presented in [8], while a low-cost impedance spectroscopy system for fuel cell characterization is described in [9].…”
Section: Introductionmentioning
confidence: 99%