2020
DOI: 10.1007/s00216-020-02386-1
|View full text |Cite
|
Sign up to set email alerts
|

A fast method for the detection of irinotecan in plasma samples by combining solid phase extraction and differential pulse voltammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
6
0

Year Published

2020
2020
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 45 publications
0
6
0
Order By: Relevance
“…In all cases, duplicate extraction recoveries did not differ by more than 6.5%. Literature studies have confirmed similar extraction recoveries from plasma, irrespective of irinotecan concentration: published recoveries were 66%-70% upon deproteinization with three volumes of 0.1% of acetic acid in methanol relative to plasma sample volume, or with one volume of acetonitrile relative to plasma sample volume 3,10,27 .…”
Section: Extraction Efficiencymentioning
confidence: 72%
See 2 more Smart Citations
“…In all cases, duplicate extraction recoveries did not differ by more than 6.5%. Literature studies have confirmed similar extraction recoveries from plasma, irrespective of irinotecan concentration: published recoveries were 66%-70% upon deproteinization with three volumes of 0.1% of acetic acid in methanol relative to plasma sample volume, or with one volume of acetonitrile relative to plasma sample volume 3,10,27 .…”
Section: Extraction Efficiencymentioning
confidence: 72%
“…Within this time range, irinotecan levels are typically above or at the LOQ of the here-in proposed assay in plasma matrix 2,24 . Additionally, quantifying irinotecan in plasma of treated patients within 0.5-3.0 h from drug infusion, when irinotecan levels are in the upper region of the therapeutic window is considered sufficient to decide on whether a subsequent dose adjustment is required 10 . Our assay in plasma may thus be useful for the purposes of personalised dose adjustment, or for calculating irinotecan AUC based on PK models.…”
Section: Useful Analytical Range Precision Lod and Loqmentioning
confidence: 99%
See 1 more Smart Citation
“…Teófilo et al used the DPV method to screen ecstasy compounds in the body using a boron-doped diamond electrode (BDD) [85]. In other research, DPV combined with solid phase extraction was used to measure irinotecan in a plasma matrix [86]. Huang, et al used a type of DPV with a triple application to increase sensitivity for the detection of DNA, as illustrated in Figure 10 [87].…”
Section: Differential Pulse Voltammetry (Dpv)mentioning
confidence: 99%
“…CYP3A4, cytochrome P-450; UGT1A1/7, UDPglucuronosyltransferase; CE, liver carboxylase adsorptive stripping square wave voltammetry and differential pulse voltammetry. These techniques were successfully applied to the detection of CPT-11 in biological samples [21][22][23]. A simple and efficient fluorimetric assay to detect the active metabolite SN-38 was also validated in plasma [24].…”
Section: Introductionmentioning