2010
DOI: 10.1016/j.epsr.2009.12.005
|View full text |Cite
|
Sign up to set email alerts
|

A fault analysis of DC electric arc furnaces with SVC harmonic filters in a mini-mill plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 11 publications
0
5
0
Order By: Relevance
“… Both sintering devices, induction furnaces and arc furnaces are heavy harmonic sources. The harmonic examination of the arc furnaces has already been done in literature well-known [10], [12], [13], [18]- [21], [23], [28]. The harmonics of an electric current assisted sintering system is to be examined in the near future by the present authors.…”
Section: The Harmful Attacksmentioning
confidence: 97%
See 1 more Smart Citation
“… Both sintering devices, induction furnaces and arc furnaces are heavy harmonic sources. The harmonic examination of the arc furnaces has already been done in literature well-known [10], [12], [13], [18]- [21], [23], [28]. The harmonics of an electric current assisted sintering system is to be examined in the near future by the present authors.…”
Section: The Harmful Attacksmentioning
confidence: 97%
“…Electric arc furnaces (EAF) are systems used for heating materials with electric arc. Arc furnaces which are also high power metallurgical devices like resistive sintering systems are commonly used in industrial settings to heat and mold metal and their power system harmonics and power requirements have been examined in literature [10], [12], [13], [18]- [21], [23], [28]. Arc furnaces range in size from only a few dozen grams (used in research laboratories for some specific purposes) to about hundreds ton units (used for high volume industrial applications).…”
Section: Introductionmentioning
confidence: 99%
“…The scientific community has most of the time adopted the PDCS output current waveforms as; -constant(DC), -AC, -pulsed DC and -pulsed DC+DC considering their polarity and shapes [4,5]. Arc furnaces which are also high power metallurgical devices like PDCS systems are commonly used in industrial settings to heat and melt metals and their power system harmonics and power requirements have been examined in literature [12][13][14][15][16][17][18][19][20][21]. However, to the best of our knowledge, utility side or power system side input harmonics and powers of a PDCS system have not been examined in literature previously.…”
Section: Introductionmentioning
confidence: 99%
“…Based on the sudden reduction of current harmonics in the fault conditions, Dehghan Marvasti et al 11 used the primary side data of EAF transformer to detect fault in the secondary side. To overcome the failure of the second harmonic filter in the static VAR compensator, Park et al 12 first concluded the reasons via various measurements. Then three solutions to suppress the transformer inrush current and another three solutions to avoid the parallel resonance were suggested.…”
Section: Introductionmentioning
confidence: 99%