2013
DOI: 10.1088/1748-0221/8/12/p12004
|View full text |Cite
|
Sign up to set email alerts
|

A feasibility study of PETiPIX: an ultra high resolution small animal PET scanner

Abstract: PETiPIX is an ultra high spatial resolution positron emission tomography (PET) scanner designed for imaging mice brains. Four Timepix pixellated silicon detector modules are placed in an edge-on configuration to form a scanner with a field of view (FoV) 15 mm in diameter. Each detector module consists of 256×256 pixels with dimensions of 55×55×300 µm 3 . Monte Carlo simulations using GEANT4 Application for Tomographic Emission (GATE) were performed to evaluate the feasibility of the PETiPIX design, including e… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
4
0

Year Published

2015
2015
2019
2019

Publication Types

Select...
2

Relationship

1
1

Authors

Journals

citations
Cited by 2 publications
(4 citation statements)
references
References 28 publications
0
4
0
Order By: Relevance
“…The performance of the virtual ring method is demonstrated in simulation using the PETiPIX scanner as a case study. PETiPIX is a small animal PET scanner with DoI capabilities, which offers exceptionally high spatial resolution (Li et al 2013). The trade-off for its high spatial resolution is relatively low detection sensitivity, which is a consequence of the use of direct detection of gamma photons and recoil electrons in silicon rather than traditional indirect detection via a scintillator crystal.…”
Section: Scanner Case Study: Petipixmentioning
confidence: 99%
See 3 more Smart Citations
“…The performance of the virtual ring method is demonstrated in simulation using the PETiPIX scanner as a case study. PETiPIX is a small animal PET scanner with DoI capabilities, which offers exceptionally high spatial resolution (Li et al 2013). The trade-off for its high spatial resolution is relatively low detection sensitivity, which is a consequence of the use of direct detection of gamma photons and recoil electrons in silicon rather than traditional indirect detection via a scintillator crystal.…”
Section: Scanner Case Study: Petipixmentioning
confidence: 99%
“…PETiPIX has already been extensively evaluated and characterised via Monte Carlo simulation, using the GATE Monte Carlo simulator with classical image reconstruction techniques (Li et al 2013). An overall spatial resolution of 0.29 mm FWHM was obtained using filtered backprojection, and sensitivity was estimated to be 0.01%.…”
Section: Scanner Case Study: Petipixmentioning
confidence: 99%
See 2 more Smart Citations