2014
DOI: 10.1007/s11801-014-3159-y
|View full text |Cite
|
Sign up to set email alerts
|

A filter array based on the variable period grating array and Fabry-Perot resonator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
3
0
1

Year Published

2017
2017
2021
2021

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 12 publications
0
3
0
1
Order By: Relevance
“…In this sense, RBC deformability can be a new biomarker and the fast and easy measurement methods are required. Former studies on RBC deformability have introduced some methodologies such as micropipette aspiration and optical tweezers where basically RBCs are stretched and the pressure or force for their extension is measured [15,16]. Whilst these studies have revealed useful RBCs mechanical properties, these methods reqire large amount of preparation and are very time consuming.…”
Section: Introductionmentioning
confidence: 99%
“…In this sense, RBC deformability can be a new biomarker and the fast and easy measurement methods are required. Former studies on RBC deformability have introduced some methodologies such as micropipette aspiration and optical tweezers where basically RBCs are stretched and the pressure or force for their extension is measured [15,16]. Whilst these studies have revealed useful RBCs mechanical properties, these methods reqire large amount of preparation and are very time consuming.…”
Section: Introductionmentioning
confidence: 99%
“…16,17 These and other techniques were thoroughly reviewed by Kim et al 18 and are useful in measuring the RBC deformation under shear flow or the rheological properties of the RBC membrane, but are generally labor intensive, time consuming, and involve a typically difficult process of manipulation. Among these methods, the micropipette aspiration is the most popular single-cell technique to measure the mechanical properties of the RBC membrane.…”
mentioning
confidence: 99%
“…Among these methods, the micropipette aspiration is the most popular single-cell technique to measure the mechanical properties of the RBC membrane. 17 Briefly, the RBC membrane is aspirated by a negative pressure through a glass micropipette, having inner diameter much smaller than the RBC average size, forcing the micropipetted RBCs to adopt an extended "tongue" shape where its length is measured under a microscope. A major drawback of this technique is that direct contact between the cell surface and the wall cannot be avoided and the extensional rate is not constant in space and time.…”
mentioning
confidence: 99%
“…Bu durum eritrositlerin şeklini tersinir olarak değiştirebilme yani deformabilite yeteneği ile mümkündür (1)(2)(3). Eritrosit deformabilitesi eritrositin geometrik şekli, sitoplazmik viskozitesi ve eritrosit membranının mekanik özellikleri tarafından belirlenmektedir (1,(4)(5)(6).…”
Section: Gi̇ri̇ş Ve Amaçunclassified