2023
DOI: 10.1016/j.jacep.2023.04.002
|View full text |Cite
|
Sign up to set email alerts
|

A Focal Ablation Catheter Toggling Between Radiofrequency and Pulsed Field Energy to Treat Atrial Fibrillation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

3
33
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 53 publications
(36 citation statements)
references
References 28 publications
3
33
0
Order By: Relevance
“…However, our results are in line with the large non‐randomized MANIFEST and EU‐PORIA registries including patients undergoing PFA PVI with the FARAPULSE™ system and reporting an arrhythmia‐free survival in PAF and persAF of 78% and 76% after 12 months 13,22 . Moreover, our data are comparable to results from a recently published study analyzing outcomes using a lattice‐tip catheter 24 . Of note, long‐term freedom from atrial arrhythmias in our study was favorable compared to findings from a trial enrolling 150 patients undergoing PFA PVI with a circular PFA catheter 11 .…”
Section: Discussionsupporting
confidence: 90%
See 2 more Smart Citations
“…However, our results are in line with the large non‐randomized MANIFEST and EU‐PORIA registries including patients undergoing PFA PVI with the FARAPULSE™ system and reporting an arrhythmia‐free survival in PAF and persAF of 78% and 76% after 12 months 13,22 . Moreover, our data are comparable to results from a recently published study analyzing outcomes using a lattice‐tip catheter 24 . Of note, long‐term freedom from atrial arrhythmias in our study was favorable compared to findings from a trial enrolling 150 patients undergoing PFA PVI with a circular PFA catheter 11 .…”
Section: Discussionsupporting
confidence: 90%
“…13,22 Moreover, our data are comparable to results from a recently published study analyzing outcomes using a lattice-tip catheter. 24 Of note, long-term freedom from atrial arrhythmias in our study was favorable compared to findings from a trial enrolling 150 patients undergoing PFA PVI with a circular PFA catheter. 11 However, our findings using the FARAPULSE™ system are not transferable to other PFA systems.…”
Section: Discussionsupporting
confidence: 48%
See 1 more Smart Citation
“…Indeed, clinical reports demonstrated frequent pulmonary vein reconnections at relook procedures despite near universal acute isolation at the initial procedure. [8][9][10][11][12][13][14] See Article by Amorós-Figueras et al…”
Section: Editorialmentioning
confidence: 99%
“…4). In this study, a cohort of 178 patients with persistent or paroxysmal atrial fibrillation underwent PFA and RF ablation [8 ▪ ]. The PFA waveforms were modified throughout the investigation (PULSE 1–2–3) and additional lines beyond the pulmonary vein isolation were added at the physician's discretion.…”
Section: The Pulse Field Ablation Systems and Multicenter Studiesmentioning
confidence: 99%