1993
DOI: 10.1259/0007-1285-66-792-1142
|View full text |Cite
|
Sign up to set email alerts
|

A frameless method for stereotactic radiotherapy

Abstract: A frameless method for stereotactic multiple arc radiotherapy (SMART) is described. Three short gold wires are implanted in the scalp approximately 100 mm apart. These are localized in a computed tomographic or angiographic study along with the target. Subsequently the gold markers are localized on beam films and the target position calculated using a computer program ISOLOC. This program provides the couch movements required to move the target to the isocentre and a micropositioner attached to the couch is us… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
12
0

Year Published

1994
1994
2019
2019

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 29 publications
(13 citation statements)
references
References 9 publications
0
12
0
Order By: Relevance
“…DISCUSSION Frameless methods have been developed for stereotactic radiosurgery, but all require some method of reliably positioning the patient with respect to the radiation source. Jones and his colleagues 7 have used gold markers implanted in the skin and a moulded semi-rigid face mask to help hold the patient in place during treatment. The gold markers have the virtue of being visible on plain radiographs, permitting their identification on beam films.…”
Section: Resultsmentioning
confidence: 99%
“…DISCUSSION Frameless methods have been developed for stereotactic radiosurgery, but all require some method of reliably positioning the patient with respect to the radiation source. Jones and his colleagues 7 have used gold markers implanted in the skin and a moulded semi-rigid face mask to help hold the patient in place during treatment. The gold markers have the virtue of being visible on plain radiographs, permitting their identification on beam films.…”
Section: Resultsmentioning
confidence: 99%
“…We have been able to conduct treatments that had a similar precision with regard to other stereotactic techniques, but employing conventional immobilisation systems [20,21].…”
Section: Discussionmentioning
confidence: 99%
“…It is advisable to use a minimally invasive procedure for the implantation of markers to avoid patient discomfort [21]. As we explained previously, the implantation process lasts no more than 30 min and it is conducted under local anaesthesia and through a puncture made on the cranium vault for placing 3 seeds, 2 mm in diameter.…”
Section: Discussionmentioning
confidence: 99%
“…surgery [22]), removable attachments [23] and implanted structures such as gold markers in fractionated prostate radiotherapy and related fields [24,25]. The latter markers are often located by means of additional imaging such as B-mode ultrasound (US) [24] or X-ray [26].…”
Section: Marker-based Methodsmentioning
confidence: 99%
“…The latter markers are often located by means of additional imaging such as B-mode ultrasound (US) [24] or X-ray [26]. Technically, registration based on fiducial markers is performed by minimizing the Euclidean distance between paired point sets coordinates [27,28], thus, resulting in the aforementioned six parameters of rigid body motion.…”
Section: Marker-based Methodsmentioning
confidence: 99%