2015
DOI: 10.1167/iovs.15-16707
|View full text |Cite
|
Sign up to set email alerts
|

A Global Shape Index to Characterize Anterior Lamina Cribrosa Morphology and Its Determinants in Healthy Indian Eyes

Abstract: Citation: Thakku SG, Tham Y-C, Baskaran M, et al. A global shape index to characterize anterior lamina cribrosa morphology and its determinants in healthy Indian eyes. Invest Ophthalmol Vis Sci. 2015;56:3604-3614. DOI:10.1167/iovs.15-16707 PURPOSE. Lamina cribrosa (LC) morphology could be implicated in the progression of glaucoma. To date, no established, quantifiable parameter to assess LC shape in vivo exists. We aim to introduce a new global shape index for the anterior LC (LC-GSI) and to identify assoc… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

2
63
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 50 publications
(65 citation statements)
references
References 39 publications
2
63
0
Order By: Relevance
“…[21][22][23] For each eye, postprocessed OCT volumes were then delineated by a single grader (TAT) using custom-written Matlab (MathWorks, Inc., Natick, MA, USA) algorithms, as previously described. 20 Specifically, the anterior LC and BMO were manually delineated. The position of the anterior LC was defined by a sharp increase in axial signal intensity (corresponding to collagen) extending laterally up to the LC insertion points in the peripapillary sclera.…”
Section: Optical Coherence Tomography Imagingmentioning
confidence: 99%
See 4 more Smart Citations
“…[21][22][23] For each eye, postprocessed OCT volumes were then delineated by a single grader (TAT) using custom-written Matlab (MathWorks, Inc., Natick, MA, USA) algorithms, as previously described. 20 Specifically, the anterior LC and BMO were manually delineated. The position of the anterior LC was defined by a sharp increase in axial signal intensity (corresponding to collagen) extending laterally up to the LC insertion points in the peripapillary sclera.…”
Section: Optical Coherence Tomography Imagingmentioning
confidence: 99%
“…This error was measured at approximately 9 lm, which is approximately twice the axial resolution of the OCT scans (4 lm). 20 We reconstructed the ONH structures in 3D, and our customized Matlab algorithms automatically derived the LC-GSI and the LC depth according to established protocols and as described below. 20 Protocol 1: Lamina Cribrosa-Global Shape Index.…”
Section: Optical Coherence Tomography Imagingmentioning
confidence: 99%
See 3 more Smart Citations